Maintenance And Service
c
ast
D
ooR
R
emovaL
:
Figure 21. Top latches for glass door (cast top and door removed)
Figure 22. Bottom Alignment Slot for glass door.
Door Latch Mechanisms
Alignment Slot
* Parts removed
for clarity*
I n order to install the log set, and
for regular cleaning, the glass door
must be removed. The cast front
must first be removed, as outlined
in the section above, before
accessing the door latches. There
are two (2) door latch mechanisms
on top the glass door as shown in
Figure 21. Each latch can be pulled
straight out and up by hand. When
the top latches are unhooked, the
door can be lifted up out of the
alignment slot at the bottom of the
firebox, shown in Figure 22.
To replace the glass door, simply
reverse the above procedure.
Warning:
Do not touch or attempt
to remove the glass door if the
fireplace is not completely cold.
WARNING: Never operate the
fireplace with the glass door
removed.
g
Lass
D
ooR
R
emovaL
:
16
Cast Top
Cast Door
The cast door on the Westley needs to be
removed whenever access to the firebox is
required. First the Westley must be turned
off and allowed to fully cool. Next, remove
the Cast Top as shown in Figure 20 by
simply lifting up. Lay the cast top down on
a towel or blanket to prevent scratching of
the finish. The cast door, with safety screen
attached, can now be removed by lifting up
to unhook it from the cast sides. Lay the
door face down on a towel or blanket to
prevent scratching of the finish. To re-install
the cast door simply reverse the procedure.
Figure 20. Cast Door Removal