![Enviro S50I Owner'S Manual Download Page 43](http://html1.mh-extra.com/html/enviro/s50i/s50i_owners-manual_2415808043.webp)
43
t
op
p
Late
c
oLLaR
i
nstaLLation
The top plate collar is an aesthetic band that helps hide the venting connection for top vent applications.
Prior to installing the venting, place the collar on top of the unit around the vent adaptor (see Figure 67).
The collar does not fasten to the unit but is heavy enough to sit in place securely.
Figure 67: Top Plate Collar Placement
Initial Installation
QUALIFIED INSTALLERS ONLY
R
eaR
v
ent
c
onveRsion
The S50 has the option to be top or rear vented. By default, it comes configured as top vented from the
factory. This can be changed by following these steps:
1.
Remove the top plate from the unit (see section
r
eMoVing
t
op
p
Late
on page 23).
2.
Remove the door frame and skirt from the unit (see section
r
eMoVing
D
oor
f
raMe
/S
kirt
on page 17).
3.
Remove the glass from the unit (see section
r
eMoVing
g
LaSS
on page 18).
4.
Remove the rear chassis from the unit (see section
r
eMoVing
r
ear
c
haSSiS
on page 19).
5.
Rotate the restrictor disk by hand from
inside the firebox until the four (4) screw
heads are exposed; remove them using
a 5/16” socket (see Figure 68). The finger
catch can be loosened and moved if it is
inhibiting the movement of the restrictor.
6.
Remove the threaded rod from the ex-
haust spigot (see Figure 69). A power drill
with a 7/16” socket and extention will be
helpful here.
7.
Remove the vent adapter from the top
of the unit by removing the four (4) T20
Remove
screws (see Figure 70). Be delicate with the gasket, you will be reusing this.
Figure 68:
Restrictor Plate Removal