Initial Installation
QUALIFIED INSTALLERS ONLY
h
oRizontaL
t
eRmination
- R
eaR
V
ent
:
12” (31 cm) Max. vent length
Max. 1 x 45
˚
Elbow
Approved horizontal termination
Figure 22. Corner Rear Vent
Approved through wall thimble
The Q2L can be installed in rear vent applications with no vertical rise within the parameters as shown in
Figures 22 and 23. If any vertical rise is required a top vent configuration should be used.
Figure 23. Flat to Wall Rear Vent
6” (15 cm) Min. vent length
18” (46 cm) Max. vent length
Approved horizontal termination
Approved through wall thimble
Note:
For every 12” (305mm)
of horizontal venting travel there
should be at least 1/4: (6.4mm) of
vertical travel.