Figure 18. Non-Combustible Clearances
m
antLe
& n
on
-c
ombustibLe
c
LeaRances
:
4 58 " (417mm)
Distance from a side wall
42"
(1067mm)
49"
(1245mm)
Unit can be placed on the floor
12" (305mm)
Mantle
2" (51mm)
Mantle
When installing the Q2L as a zero clearance fireplace the correct clearances and materials must be used:
a
boVe
u
nit
:
A minimum 10” of non-combustible facing material, with a R-Value no less than 0.26, must
be used above the unit (in front of the included steel framing plate).
i
n
f
Ront
of
u
nit
:
The Q2L can be placed on the floor if desired although it is recommended that it be
raised aleast an inch or higher for more heat sensetive materials such as carpet or linoleum.
a
Djacent
/s
iDewaLL
:
There must be a minimum distance of
4 5/8” (417mm)
from the side of the Q2L
cabinet to an adjacent wall composed of combustible material (see Figure 18).
m
antLe
:
It is not necessary to install a mantle, but if one is desired the guidelines as shown in Figure 19.
Initial Installation
QUALIFIED INSTALLERS ONLY
Page 18