FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All ENVIRO gas-fired appliances must be installed 

in accordance with their instructions. Carefully read all 

the instructions in this manual first. Consult the building 

authority having jurisdiction to determine the need for 

a permit prior to commencing the installation.
•    NOTE:  Failure  to  follow  these  instructions  could 

cause  a  malfunction  of  the  fireplace,  which  could 

result in death, serious bodily injury, and/or property 

damage.
•  Failure to follow these instructions may also void 

your fire insurance and/or warranty.

GENERAL
•  Installation  and  repair  should  be  done  by  a 

qualified  service  person.  The  appliance  should  be 

inspected before the first use and, at least, annually 

by  a  qualified  service  person.  More  frequent 

cleaning  may  be  required  due  to  excessive  lint  from 

carpeting, bedding material, etc.  It is imperative the 

control  compartments,  burners  and  circulating  air 

passageways of the appliance be kept clean.
•  Due  to  high  temperatures,  the  appliance  should 

be  located  out  of  high  traffic  areas  and  away  from 

furniture and draperies.
Children  and  adults  should  be  alerted  to  the 

hazards  of  high  surface  temperatures  and 

should  stay  away  to  avoid  burn  or  clothing 

ignition.
•  Young  children  should  be  carefully  supervised 

when in the same room as the appliance.
•  Clothing or other flammable materials should not 

be placed on or near the appliance.

FOR YOUR SAFETY
•  Installation and service must be performed by a 

qualified installer, service agency or gas supplier.
•  This installation must conform to local codes or, in 

the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas 

Code ANSI Z223.1.2 (USA)

•  To  prevent  injury,  do  not  allow  anyone  who  is 

unfamiliar with the stove to operate it.
  To  prevent  injury,  if  the  pilot  or  pilot  and 

burners have gone out on their own, open the 

glass door and wait 5 minutes to air out before 

attempting to re-light the stove.
•  Always  keep  the  area  around  these  appliances 

clear  of  combustible  material,  gasoline  and  other 

flammable liquids and vapours.
•  These appliances should not be used as a drying 

rack for clothing or for hanging Christmas stockings/

decorations.
•  Due to the paint curing on the stove, a faint odor 

and  slight  smoking  will  likely  be  noticed  when  the 

stove is first used.  Open a window until the smoking 

stops.
Always connect this gas stove to a vent system and 

vent  to  the  outside  of  the  building  envelope.  Never 

vent to another room or inside the building. Make sure 

the specified vent pipe is used, properly sized and of 

adequate  height  to  provide  sufficient  draft.    Inspect 

the venting system annually for blockage and signs of 

deterioration.
WARNING: Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts  specifically  approved  with  this  appliance,  may 

result in property damage or personal injury.
WARNING:  Do  not  operate  with  the  glass  front 

removed,  cracked  or  broken.    Replacement  of  the 

glass should be done by a licensed or qualified service 

person.
•  Never  use  solid  fuels  such  as  wood,  paper, 

cardboard, coal, or any flammable liquids, etc., in this 

appliance.
•  Do not use this heater if any part has been under 

water. Immediately call a qualified service technician 

to inspect the heater and to replace any part of the 

control or gas control systems that have been under 

water.
•  Do not abuse the glass by striking it or slamming 

the door shut.

Safety Precautions

Summary of Contents for EG40 DV NG

Page 1: ...life Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other Flammable vapours and liquids in the v...

Page 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Page 3: ...aration For Installation 12 Clearances to Combustibles 12 Planning Your Installation 13 Corner Installations 14 Mobile Home Installation 14 Vent Termination Restrictions 15 Freestanding Direct Vent Ki...

Page 4: ...label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a listed wall thermostat IN USA see current ANSI Z223 1 for installation instruction...

Page 5: ...mensions 25 635 mm 21 533 mm 12 1 2 318 mm 4 5 8 117 mm 29 1 8 740 mm Shipping Weight 256 lbs 116 kg Figure 1 EG40 Exterior Dimensions Rating Label Location The rating label is found inside the right...

Page 6: ...attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace...

Page 7: ...e of medium height If the flames look like this no venturi adjustment is needed If the flames are fairly short and mostly blue the fireplace is getting too much air Therefore the venturies should be c...

Page 8: ...roblem Depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available...

Page 9: ...bers and the door has been resealed re light the pilot following the instructions on the lighting label attached to the unit Cleaning Plated Surfaces It is important to note that fingerprints and othe...

Page 10: ...arbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper or...

Page 11: ...ure 12 O ring on valve screw is similar to what is shown in Figure 6 On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly install...

Page 12: ...ceiling joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in...

Page 13: ...from the appliance flue outlet to the ceiling the ceiling thickness the vertical rise through the attic or second story and allow for sufficient vent height above the roof line For two story applicati...

Page 14: ...ation must be in accordance with the Manufactured Home Construction and Safety Standard UL 307B Title 24 CFR Part 3280 and or The Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A Hol...

Page 15: ...12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 c...

Page 16: ...aged INSTALLATION INSTRUCTIONS 1 Decide on a location for the unit that will meet any or all local code requirements Refer Planning Your Installation and Clearances to Combustibles 2 Set the appliance...

Page 17: ...crews evenly spaced 12 Dress the flex liner through the wall thimble and attach the vent terminal to the outside of the house using four 4 wood screws provided The use of non hardening mastic should b...

Page 18: ...w in the tab on the inside finished collar This will prevent the pipe from being disconnected at the vent terminal 23 Light the appliance and ensure proper operation Other Approved Vent Parts Table 3...

Page 19: ...p 988 4DT WS B SV4BM 4DWS Wall strap support band 970 4DT HKA SV0SHK 4DHTK1 Horizontal termination kit SD Basic Kit SEL Kit A SC Standard Kit 911 11 to 14 pipe adjustable 4DT AJ 4D12A 4 to 10 pipe adj...

Page 20: ...ination of rise and run can be used as long as it lays within the shaded area a total of three 3 90 elbows or six 6 45 elbows can be used In addition to what is shown if a 90 elbow is used in the hori...

Page 21: ...Wall Thimble Strap Sheet metal screws Fold strap here 11 4 3 2cm Figure 26 Installing Decorative Wall Thimble 10 254mm 10 254mm Figure 25 Wall Framing Hole for Horizontal Installation Initial Install...

Page 22: ...a chase the minimum clearance to combustibles is 2 5 cm Wood screws x4 Cut vinyl siding away to fit standoff Bolt x4 required Nut x4 required Wood screw x4 required Figure 27 Installing Vent Cap with...

Page 23: ...le drilled in Step 2 Frame the hole as shown in Figure 29 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance Vertical Termination Storm Collar Flashing Roofi...

Page 24: ...er the pipe and push it down to the top of the roof flashing as shown in Figure H Dimension H obtained from table below Table 5 Minimum H for Figure 31 Roof Pitch Minimum Height Ft Meters Flat to 7 12...

Page 25: ...eiling and roof at this point From the roof locate the drill hole and mark the outline of the Cathedral Ceiling Support Box 3 Remove shingles or other roof coverings as necessary to cut the rectangula...

Page 26: ...install the flex liner to the retro adapter Fully line the CLASS A chimney with a minimum 4 10 cm flex liner to the top of the CLASS A chimney Place a bead of high temperature silicone to the Simpson...

Page 27: ...0 in the U S WARNING Electrical grounding instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and must be plugged directly into a properl...

Page 28: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water soluti...

Page 29: ...embly See Figure 31 or 34 for proper ember placement DO NOT pack this ember material as this could create an unsafe condition leave embers loose Carefully remove logs from box Check to ensure there is...

Page 30: ...t up watch for ignition to ALL burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making sure...

Page 31: ...screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas l...

Page 32: ...ght Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Body Wiring Harness EC 037A Burner Wiring Harness EC 037B Fan Control Knob EC 040 IEC Power Cord 115V EC 043 4 oz Bag Coal Embers Only EC...

Page 33: ...or Hinge Set of 2 EG40 302 21 Fan Mount EG40 304 22 Pedestal Box Cover EG40 307 23 Burner Control Assembly NG 30 014 23 Burner Control Assembly LP 30 015 24 Front Pan Burner 30 016 25 Rear Burner with...

Page 34: ...Parts Diagram Chassis 15 1 28 21 14 22 18 19 12 17 7 13 EG 40 Body Chassis July 2004 34...

Page 35: ...35 Parts Diagram Gas Tray Door EG40 Gas Tray Door Assemblies July 2004 27 8 20 9 23 2 4 5 10 6 11 16 26 25 24 3...

Page 36: ...ust be provided by you or the dealer including serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result...

Page 37: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Reviews: