![Enttec Pixelator User Manual Download Page 7](http://html.mh-extra.com/html/enttec/pixelator/pixelator_user-manual_2415442007.webp)
PIXELATOR (70060)
Visit the ENTTEC website for the latest version.
..
USER MANUAL
7
|
ID: 2114
Hardware version: RevC
Document Updated: May 2021
Selection Menu
1-load profile
2-Setup
3-Status
4-Lock Unit
5-Restart
1-Load Profile:
Lists all available profiles on the PIXELATOR, list can be scrolled using up & down keys.
Scrolling indicator is visible when the list allows scrolling. Pressing Enter at the selected profile will activate
the profile.
2-Setup:
Setup screen allows changing the IP address of the unit via “Change IP” or doing Factory Reset.
1-Change IP
2-Factory Reset
Change IP:
This screen further gives two options DHCP or Static IP. When Static IP is selected, the screen
allows you to change the IP address using the top and bottom button to scroll the digits and the menu
& enter buttons to select the segment. Once you are on the last segment of the IP address, pressing the
Enter button, will activate the IP address. It will take a few seconds for the change to go through, please
wait 30 seconds, before attempting to try again.
Change IP Address
IP: 192.168.001.003
Factory Reset:
Activating Factory Reset, leads to a simple prompt confirming your action. Once
confirmed, the Factory Reset will take a few seconds to run. It will end up deleting all your user created
profiles, as well as any saved settings. Please use this only when needed, or as directed by ENTTEC
support team.
F-Reset in progress
please wait …
3-Status:
Provides read-only information for both the system and the network. These require no user-input
and serve as a way of checking the performance of the unit.
1-System