Profiles 

Within this window you can create, manage, and 

activate  Profiles  within  the  PIXELATOR.  Profiles 

allow you to configure that Data is sent to the 24 

outputs,  as  well  as  allowing  you  to  change 

between  profiles  during  the  installation  if 

required. 

 

The  PIXELATOR  comes  with  some  Read-Only 

profiles on the PIXELATOR as default, these will be 

displayed within the ‘Remarks’ column. These will 

reappear after a Factory Reset. 

 

Use the radio button under the ‘Active’ column to select a Profile to use the functionality along the bottom 

of the page. Clicking on the Profile name will launch the profile in the profile editor window. 

 

Profile Editor:

 

Create  a  new  profile  or  edit  an  existing  one 

using the profile-editor. Profile Editor opens in 

a  new  page  in  your  web  browser.  Select  a 

module  on  the  left  and  the  right  panel  will 

provide  help  about  that  panel.  Connect  a 

module to another using wires from one point 

to another.

 

The direction of the wire (arrow) is important, 

the  arrow  signifies  output,  and  reflects  the 

flow of data. The same PLINK port# cannot be 

re-used within the same profile.

 

 

Profile Modules:

 

Each profile is made up of two or more connected Modules or Actions. The relationship between them 

forms the layout of the data flow within the profile. The following modules are available:

 

 

PLINK 1U:

 The PLINK 1U module represents one of the physical ports on the rear of this unit, and maps 

to 1 Universe. Within this Module you will need to select:

 

 

Protocol:

 select the led protocol that the pixel tape conforms to.

 

 

Ordering:

 RGB or RGBW mapping that the pixel tape conforms to. RGB modes 

use 3 DMX slots per LED pixel, and RGBW modes use 4 DMX slots.

 

 

Grouping:

 it allows one DMX pixel to drive multiple physical LED pixels  

 

 

Start-Ch:

 DMX Start Channel for the 1st pixel can be changed as needed.

 

 

 

PLINK 2U:

 The PLINK 2U module represents one of the physical ports on the rear of this unit, and maps 

to 2 Universe. Within this Module you will need to select:

 

 

Each  PLINK  2U  module  has  2  input  nodes  that  can  be  connected  to  two 

Ethernet streams. Top one (U1) is mapped to the First universe and Bottom 

one (U2) is mapped to the Second universe relative to the pixel-tape.

 

 

Protocol: select the led protocol that the pixel tape conforms to.

 

 

Ordering: RGB or RGBW mapping that the pixel tape conforms to.

 

 

Summary of Contents for Pixelator

Page 1: ...since all data conversion is processed on the PIXELATOR the P Link injector is kept as compact as possible Depending on the application choose between the indoor or outdoor IP PLINK INJECTORs ensurin...

Page 2: ...ce 9 Home 9 Profiles 10 Settings Firmware Update 11 Backup and Restore 12 Stream Auditor 12 Servicing Inspection Maintenance 13 Cleaning 13 Package Contents 14 Ordering Information 14 Safety Ensure yo...

Page 3: ...e providing power to the device System Planning and Specification To contribute to an optimal operating temperature where possible keep this device out of direct sunlight This unit has an IP20 rating...

Page 4: ...Visit the ENTTEC website for the latest version USER MANUAL 4 ID 2114 Hardware version RevC Document Updated May 2021 Physical Dimensions All dimensions are in millimetres unless specified otherwise...

Page 5: ...orts 1 to 24 Artnet48 Pixel24 This profile will take 48 Art Net universes and convert them to 24 Pixel Link streams on ports 1 to 24 Each Port will be mapped to 2 Art Net Universes consecutively Profi...

Page 6: ...nector un used 2 USB Ports un used LCD Menu The LCD Menu is navigated through the four panel buttons on the front of the unit The Menu button acts as the Back button which takes you to the previous Me...

Page 7: ...IP address using the top and bottom button to scroll the digits and the menu enter buttons to select the segment Once you are on the last segment of the IP address pressing the Enter button will acti...

Page 8: ...e restart will be complete once the Main Menu is displayed System Restarting Please wait Out of the Box As default the PIXELATOR will have the Artnet48 Pixel24 Profile active this profile will take 48...

Page 9: ...the local network to return a list of active devices on a local network Devices can be discovered using Art Poll i e DMX Workshop if set to use ArtNet The device Default IP address will be printed on...

Page 10: ...signifies output and reflects the flow of data The same PLINK port cannot be re used within the same profile Profile Modules Each profile is made up of two or more connected Modules or Actions The re...

Page 11: ...ever Will only refresh Pixe Link when Synced Stream is received Settings Firmware Update The PIXELATOR s settings can be configured within the Settings tab Firmware Update The latest firmware can be d...

Page 12: ...ormatting displayed on the web interface Warning This will replace any settings options and profiles on the PIXELATOR Individual Profile Export This will export a single profile from the PIXELATOR whi...

Page 13: ...is cleaned in a schedule fit for the environment it is installed within to ensure maximum product longevity Cleaning schedules will vary greatly depending on the operating environment Generally the mo...

Page 14: ...pdated May 2021 Package Contents PIXEATOR Ethernet Cable IEC cable Ordering Information For further support and to browse ENTTEC s range of products visit the ENTTEC website Item Part No PIXELATOR 700...

Reviews: