ePRO Door Entry System with Entrotec Connect Server
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
Door controller with PSU to
each Call Point:
2x Cat5e or Cat6.
B
Lock Relay to locks:
2x 1.5mm² multi-stranded flex or singles (route through
any exit/fire switch or break glass for fail safe operation).
C
Lock Relay to exit switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
D
Lock Relay to fire switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
FIGURE 1-2
NOTE
Refer to the PRO-DC (Door Controller) Installation Guide for Lock and Exit Switch connections.