Cable Specification
4
1
Cable Specification
The cabling system is based on Unshielded Twisted Pair
Category 5e
(Cat5e) or
Category 6
(Cat6).
The cable must be
annealed pure copper
, meeting or exceeding the requirements defined in the
standard ANSI/TIA 568 C.2.
Failure to comply with this cable specification may result in erratic operation of equipment.
Typical Configurations
1.1.1
One-Way System
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
PSU to Call Point:
2x 1.5mm² multi-stranded flex or singles
or
1x Cat5e or Cat6.
B
PSU to Apartment Station:
2x 1.5mm² multi-stranded flex or singles
or
1x Cat5e or Cat6.
C
Call Point to Apartment Station:
1x Cat5e or Cat6.
FIGURE 1-1 - PRO-KIT-1W