Entrotec PRO-DPA Installation And Setup Manual Download Page 2

Legal

 

 

2

 

Legal and Copyright Notice

 

Entrotec regularly develop and enhance product lines, these changes will be included in the latest 
documentation.  Whilst every effort has been made to ensure the accuracy of the information 
supplied herein, Entrotec is not responsible for any errors or omissions.  Many of the images 
shown are for illustration purpose only.  The actual product may vary due to product enhancement 
or custom configurations.  The materials contained in this document are protected and may be 
subject to intellectual property rights.

 

 

Copyright 2021 Entrotec Limited.  All rights reserved.

 

Installation Specification

 

It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well 
as ALL relevant wiring regulations.  Failure to comply with Entrotec’s installation and cable 
specification may result in erratic operation of equipment and could invalidate any warranty.

 

 

Installations must comply with the following applicable standards:

 

 

BS 7671

: Requirements for electrical installations.  IET Wiring Regulations 18th Edition.

 

 

The Electricity at Work Regulations 1989

 

 

ANSI/TIA-568.0-D

: Generic Telecommunications Cabling for Customer Premises.

 

 

ANSI/TIA-568.1-D

: Commercial Building Telecommunications Cabling Standard.

 

IET Wiring Regulations 18th Edition: Regulation 444 (MEASURES AGAINST ELECTROMAGNETIC 
DISTURBANCES) imposes requirements for segregation of circuits.

 

 

IET Wiring Regulations 18th Edition: Regulation 528 (PROXIMITY TO WIRING SYSTEMS TO OTHER 
SERVICES) imposes requirements for segregation of door entry / access control circuits (Band I), 
230VAC mains circuits (Band II) and other higher voltage circuits.

 

 

IET Wiring Regulations 18th Edition: Regulations 541 and 542 impose requirements for earthing 
and bonding conductors.  Ensure ALL metalwork is bonded to the buildings earth, this includes Call 
Points, exit switches, cabinets and metal conduit.  Ring terminals and earth points are provided on 
Call Points and cabinets to terminate earth cables, ensure these connections are made.

 

 

  

 

 

 

WARNING - ISOLATION OF ELECTRICAL EQUIPMENT

 

In compliance with 

The Electricity at Work Regulations 1989,

 electrical equipment should be 

made dead to prevent danger while work is carried out on or near that equipment.  No person 
shall be engaged in any work activity on or so near any live conductor.

 

 

Warranty and Support

 

Entrotec systems are renowned for their reliability and have a 2-year warranty on all Entrotec 
manufactured products as standard.  This warranty does not cover water damage, vandalism, 
mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.

 

 

Entrotec offer complimentary training courses and telephone support:

 

01506 886 235 - 

8:30am to 5pm Mon-Thurs and 8:30am to 4pm Friday.

 

[email protected]

 

Summary of Contents for PRO-DPA

Page 1: ...PRO DPA Installation and Setup Guide with PRO AS7 Issue 001...

Page 2: ...th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS...

Page 3: ...rview 6 PRO DPA Call Point 6 3 Connections 7 4 Factory Default Settings 8 5 Provision 8 Provisioning One Way Systems without an Entrotec Connect Server 8 Provisioning Systems with an Entrotec Connect...

Page 4: ...is cable specification may result in erratic operation of equipment Typical Configurations 1 1 1 One Way System The specification below shows the minimum cable requirements allow for extra cabling if...

Page 5: ...r with PSU to each Call Point 2x Cat5e or Cat6 B Lock Relay to locks 2x 1 5mm multi stranded flex or singles route through any exit fire switch or break glass for fail safe operation C Lock Relay to e...

Page 6: ...ew 6 2 Overview PRO DPA Call Point 2 1 1 Front View FIGURE 2 1 Microphone Panel Camera Call Button Speaker 2 1 2 Back View FIGURE 2 2 Tamper Switch Network Power and Data Connections A B C D A B A B C...

Page 7: ...Cable Type Detail RS485 to Door Controller 1x Cat5e or Cat6 1 Pair UTP RS485A RS485B 1 2 12VDC from Door Controller PSU 1 Pair UTP 12v Red 2 Pair UTP 0v Black Ethernet to Door Controller 1x Cat5e or C...

Page 8: ...nnect Server For one way systems without an Entrotec Connect Sever the Call Point can be connected to an apartment station adopting a peer to peer P2P network connection The system configuration is pe...

Page 9: ...port entrotec co uk Tap OK FIGURE 5 2 iii A list of the devices connected to the network will be displayed VTO references to PRO DPA Local identifies the apartment station you are operating Select the...

Page 10: ...nter and confirm the password for the PRO DPA The Email address is used for password recovery default support entrotec co uk Tap OK FIGURE 5 4 v The PRO DPA will now show on the list as Initialised Ta...

Page 11: ...Provision 11 vi Select the PRO DPA and tap Edit FIGURE 5 6 vii Make sure the Call Point is set a Main Press OK FIGURE 5 7...

Page 12: ...Provision 12 viii Edit the PRO AS7 Enter a new IP address and tap OK FIGURE 5 8 ix Tap Quick Config This will apply the new settings to the Call Point and the Apartment Station FIGURE 5 9...

Page 13: ...onfigure the Call Point for synchronisation with the server follow the steps in the sections below 5 2 1 Connect to Web Service and Initialise Device i Connect a laptop or PC to the same network as th...

Page 14: ...to the same network as the Call Point ii Assign the laptop PC an IPv4 address from the same range used by the door entry system iii Use a web browser and enter the IP address of the Call Point in to t...

Page 15: ...VDP SIP Server Username and SIP Server Password vii Press Save NOTE The device will reboot if the internal device SIP Server is enabled or disabled 5 2 4 Configure the Alternate SIP Server After apply...

Page 16: ...ion with the SIP server please refer to the Entrotec Connect Quick Setup Guide 5 2 6 Destination SIP ID i Navigate to Local Settings Basic ii Enable and set the Block No to match that of the Apartment...

Page 17: ...NOTE The maximum resolution is 720P The PRO AS7 Apartment Station display resolution is 480x800 therefore it may be most efficient to use the WVGA Video Format Lock Release Time i Login to the Call P...

Page 18: ...ttings Access Control RS485 vi Set the Unlock Response Interval and Unlock Time for the desired lock release time vii Press Save these settings update the parameters for the remote lock relay in the c...

Page 19: ...Notes 19...

Page 20: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235 www entrotec com...

Reviews: