Entrotec PRO-DPA Installation And Setup Manual Download Page 15

 

 

Provision

 

 

 

 

15

 

5.2.3

 

Configure Call Point SIP Server Settings

 

i.

 

Navigate to 

Network Settings

 > 

SIP Server

.

 

 

FIGURE 5-15

 

ii.

 

Uncheck 

Enable

; this disables the internal device SIP Server which is on by default.

 

iii.

 

For 

Sever Type

 select 

Entrotec Connect

.

 

iv.

 

Enter the Entrotec Connect Server 

IP Address

 

v.

 

Change 

Port 

to

 5080

.

 

vi.

 

Optional

 - enter the 

Domain VDP

SIP Server Username

 and 

SIP Server Password

.

 

vii.

 

Press 

Save

.

 

  

 

 

 

NOTE

 

The device will reboot if the internal device SIP Server is enabled or disabled.

 

 

5.2.4

 

Configure the Alternate SIP Server

 

After applying the 

SIP server 

settings in Section 5.2.3, the Call Point can be configured to operate 

as an alternate SIP Server and take over from the main SIP server to prevent any down time.

 

i.

 

Check the 

Alternate Server

 box.  The fields above will be greyed out and populated with the 

Call Point details.

 

 

FIGURE 5-16

 

ii.

 

Click 

Save

 to save the configuration.  

 

Summary of Contents for PRO-DPA

Page 1: ...PRO DPA Installation and Setup Guide with PRO AS7 Issue 001...

Page 2: ...th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS...

Page 3: ...rview 6 PRO DPA Call Point 6 3 Connections 7 4 Factory Default Settings 8 5 Provision 8 Provisioning One Way Systems without an Entrotec Connect Server 8 Provisioning Systems with an Entrotec Connect...

Page 4: ...is cable specification may result in erratic operation of equipment Typical Configurations 1 1 1 One Way System The specification below shows the minimum cable requirements allow for extra cabling if...

Page 5: ...r with PSU to each Call Point 2x Cat5e or Cat6 B Lock Relay to locks 2x 1 5mm multi stranded flex or singles route through any exit fire switch or break glass for fail safe operation C Lock Relay to e...

Page 6: ...ew 6 2 Overview PRO DPA Call Point 2 1 1 Front View FIGURE 2 1 Microphone Panel Camera Call Button Speaker 2 1 2 Back View FIGURE 2 2 Tamper Switch Network Power and Data Connections A B C D A B A B C...

Page 7: ...Cable Type Detail RS485 to Door Controller 1x Cat5e or Cat6 1 Pair UTP RS485A RS485B 1 2 12VDC from Door Controller PSU 1 Pair UTP 12v Red 2 Pair UTP 0v Black Ethernet to Door Controller 1x Cat5e or C...

Page 8: ...nnect Server For one way systems without an Entrotec Connect Sever the Call Point can be connected to an apartment station adopting a peer to peer P2P network connection The system configuration is pe...

Page 9: ...port entrotec co uk Tap OK FIGURE 5 2 iii A list of the devices connected to the network will be displayed VTO references to PRO DPA Local identifies the apartment station you are operating Select the...

Page 10: ...nter and confirm the password for the PRO DPA The Email address is used for password recovery default support entrotec co uk Tap OK FIGURE 5 4 v The PRO DPA will now show on the list as Initialised Ta...

Page 11: ...Provision 11 vi Select the PRO DPA and tap Edit FIGURE 5 6 vii Make sure the Call Point is set a Main Press OK FIGURE 5 7...

Page 12: ...Provision 12 viii Edit the PRO AS7 Enter a new IP address and tap OK FIGURE 5 8 ix Tap Quick Config This will apply the new settings to the Call Point and the Apartment Station FIGURE 5 9...

Page 13: ...onfigure the Call Point for synchronisation with the server follow the steps in the sections below 5 2 1 Connect to Web Service and Initialise Device i Connect a laptop or PC to the same network as th...

Page 14: ...to the same network as the Call Point ii Assign the laptop PC an IPv4 address from the same range used by the door entry system iii Use a web browser and enter the IP address of the Call Point in to t...

Page 15: ...VDP SIP Server Username and SIP Server Password vii Press Save NOTE The device will reboot if the internal device SIP Server is enabled or disabled 5 2 4 Configure the Alternate SIP Server After apply...

Page 16: ...ion with the SIP server please refer to the Entrotec Connect Quick Setup Guide 5 2 6 Destination SIP ID i Navigate to Local Settings Basic ii Enable and set the Block No to match that of the Apartment...

Page 17: ...NOTE The maximum resolution is 720P The PRO AS7 Apartment Station display resolution is 480x800 therefore it may be most efficient to use the WVGA Video Format Lock Release Time i Login to the Call P...

Page 18: ...ttings Access Control RS485 vi Set the Unlock Response Interval and Unlock Time for the desired lock release time vii Press Save these settings update the parameters for the remote lock relay in the c...

Page 19: ...Notes 19...

Page 20: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235 www entrotec com...

Reviews: