4 Technical specifications
9
Issue 2020-08-31
1021444-2.0
4
Technical specifications
Ensure that the door operator with technical specification below is suitable for the installation.
Manufacturer:
Entrematic
Address:
221A Racco Parkway Vaughan Canada
Type:
Ditec HA7
Power supply:
120 V AC +10/-15%, 50/60 Hz, mains fuse max 10A (building
installation)
Power consumption:
Max. 90 W
Auxiliary voltage:
24 V DC, max. 400 mA (max. 1000 mA including lock)
Max. weight/width:
200 Lbs.
Note!
Refer to section 4.1 and the appropriate standard
(ANSI/BHMA A156.19) for door forces and speeds as related to
door weight and width.
Door width:
762 - 1219 mm (30 - 48”)
Electro-mechanical locking
device:
Selectable: 12V DC, max. 1200 mA or 24 V DC, max. 600 mA
Door opening angle:
PUSH arm: 80° - 110°, with reveal 0 - 130 mm (0 - 5 1/8")
PULL arm: 80° - 110°, with reveal 0 - 51 mm (0 - 2")
Opening time (0° - 80°):
Variable between 4.5 - 9 s
Closing time (90° - 10°):
Variable between 4.5 - 9 s
Impulse time delay:
2 s - 6 h
Ambient temperature:
-4 °F to +113 °F (-20 °C to +45 °C)
Relative humidity:
Max. 95%
Drive unit weight:
7.5 lb. (3.4 kg)
Class of protection:
IP20
Approvals:
Third party approvals from established certification organizations
valid for safety in use, see Declaration of Conformity.
Complies with: UL 10C, ANSI/BHMA A156.19 and UL 325
Summary of Contents for Ditec HA7
Page 1: ...Installation and Service Manual Swing Door Operator Ditec HA7 Trusted brands Great products ...
Page 13: ...6 Part identification 13 Issue 2020 08 31 1021444 2 0 6 Part identification ...
Page 22: ...10 Mechanical installation 22 Issue 2020 08 31 1021444 2 0 ...
Page 23: ...10 Mechanical installation 23 Issue 2020 08 31 1021444 2 0 ...
Page 24: ...10 Mechanical installation 24 Issue 2020 08 31 1021444 2 0 ...
Page 25: ...10 Mechanical installation 25 Issue 2020 08 31 1021444 2 0 ...
Page 26: ...10 Mechanical installation 26 Issue 2020 08 31 1021444 2 0 ...
Page 27: ...10 Mechanical installation 27 Issue 2020 08 31 1021444 2 0 ...
Page 29: ...10 Mechanical installation 29 Issue 2020 08 31 1021444 2 0 ...
Page 30: ...10 Mechanical installation 30 Issue 2020 08 31 1021444 2 0 ...
Page 31: ...10 Mechanical installation 31 Issue 2020 08 31 1021444 2 0 ...
Page 32: ...10 Mechanical installation 32 Issue 2020 08 31 1021444 2 0 ...
Page 33: ...10 Mechanical installation 33 Issue 2020 08 31 1021444 2 0 ...
Page 34: ...10 Mechanical installation 34 Issue 2020 08 31 1021444 2 0 ...
Page 37: ...11 Electrical connection 37 Issue 2020 08 31 1021444 2 0 11 2 Control unit CU ...
Page 41: ...12 Start up 1021444 2 0 Issue 2020 08 31 41 12 2 4 Test 12 2 5 Settings ...
Page 42: ...42 Issue 2020 08 31 1021444 2 0 12 Start up 12 2 6 Add user 0 12 2 7 Remove user ...
Page 49: ......