78
IP2179EN - 2015-11-24
TOP603H
Menu
Function, setting range, unit
Value
Factory
settings
Deceleration distance on opening
0 = 0cm
1 = 7cm
2 = 14cm
...
9 = 63cm
0 - 9
Deceleration distance on closing
0 = 0cm
1 = 7cm
2 = 14cm
...
9 = 63cm
0 - 9
Deceleration speed on closing (mm/s)
0 = 50mm/s
9 = 140mm/s
0 - 9
Disengagement on the closing stop
0 = disabled
1 = enabled
0 - 1
Direction selection
0 = disabled
1 = enabled
This setting is only possible if the EMERGENCY STOP
connector (1, green) is disconnected.
0 - 1
Thrust adjustment on obstacles during opening
0 - minimum thrust
9 - maximum thrust
0 - 9
Thrust adjustment on obstacles during closing
0 - minimum thrust
9 - maximum thrust
NB: after detecting an obstacle during a closing operation, the
door reverses its stroke for about 800mm. Automatic closure
is disabled (if active) and the courtesy light flashes for about
10 min.
WARNING: to ensure the closing thrust force values return
within the limits established by Standard EN12453, you must
set a value of 1 for parameter A6. This operation must be
carried out by qualified personnel.
0 - 9
Door type:
0 = sectional door
1 = side sectional door with disengagement on obstacle
during opening too
2 = side sectional door / tilting door with soft start
If A7 has been modified, perform a reset then repeat the
learning operation (chapter 15).
0 - 2
Early switch-on of courtesy light for opening and closing (sec.)
0 = disabled
1 = min 2 sec
8 = max 16 sec
0 - 8
18. Parameters TOP603H