95
IP2179EN - 2015-11-24
26. Maintenance
Replacing the fuse
Disconnect the mains plug.
• Remove the cover from the pulling unit.
• Take the faulty fuse S1 (S2) out of the fuse-holder and replace it. Make sure the new fuse is of
the correct value.
• Replace the pulling unit cover.
Restore the mains connection.
Replacing the courtesy light
Disconnect the mains plug.
•
Remove the diffuser from the pulling unit.
•
Replace the E14-40 W light bulb (max 60W
or equivalent).
WARNING: handle with care since the light bulb
may be very hot.
NB: some energy-saving bulbs may interfere
with the radio signal.
•
Replace the diffuser on the pulling unit.
•
Restore the mains connection.
1.
2.
3.
4.
5.
S1
S2
Monthly maintenance tasks
•
Check the emergency release is working properly.
•
Check the safety devices (if installed) are working properly.
•
Check the obstacle detection function is working properly.
Six-monthly maintenance tasks
•
Check the stability of the automation and make sure the screws and nuts are correctly tight-
ened.
(E14-max. 60W)