10GBASE XENPAK PHY Specifications
A-6 Specifications
10GBASE XENPAK PHY Specifications
At
the
time
of
printing
of
this
manual,
there
are
four
10GBASE
XENPAK
modules
available.
Tables A
‐
12
through
A
‐
14
provide
the
specifications
for
each
XENPAK
module.
Table A-13
provides you with the input/output specifications for each version of XENPAK.
Table A
‐
14
provides
you
with
the
necessary
information
to
make
decisions
concerning
the
cable
type,
maximum
length,
and
connector
type
according
to
each
XENPAK
module.
Table A-12 XENPAK Port, Physical, and Environmental Specifications
Item
Specification
Port
One Port
Port interface that can support a full 10 Gbps throughput.
Physical
Dimensions
11.33 H x 3.48 W x 1.17 D (cm)
4.46 H x 1.37 W x 0.46 D (in.)
Approximate Weight
Net:
0.13 kg (0.29 lbs)
Environmental
Operating Temperature
5° to 40° C (41° to 104° F)
-30° to 73° C (-22° to 164° F)
Storage Temperature
-30° to 73° C (-22° to 164° F)
Operating Relative Humidity
5% to 90% (non-condensing)
Table A-13 XENPAK Fiber-Optic Specifications
XENPAK PHY
Output Power
Extinction
Ratio
Received
Sensitivity
Link Budget
10GBASE-LR
<0.5 dBm
>4 dB
-10.28 dBm
0 to 9.4 dB
10GBASE-ER
<4.0 dBm
>3 dB
-10.3 dBm
5 to 11 dB
10GBASE-LX4
<0.5 dBm
>3.5 dB
-10.3 dBm
-13.4 dBm
(on 10
μ
m fiber)
0 to 7.5 dB
0 to 8.2 dB
(on 10
μ
m fiber)
10GBASE-SR
<-1 dBm
>3 dB
-11.1 dBm
7.3 dB
Table A-14 Recommended Cable Types and Specifications
XENPAK PHY
Type
Max. Length
Connector
10GBASE-LR
SMF
10 km (6.21 mi)
SC
10GBASE-ER
1
1. The 10GBASE-ER XENPAK requires a minimum of 5 dB attenuation or a cable length of about 10 km.
SMF
40 km (24.85 mi)
SC
10GBASE-LX4
SMF
MMF
10 km (6.21 mi)
300 m (984.25 ft)
SC
10GBASE-SR
62.5 um MMF 200Mhz/km
50 um MMF 400Mhz/km
50 um MMF 2000Mhz/km
33 m (108 ft)
66 m (217 ft)
300 m (884 ft)
SC
SC
SC
Summary of Contents for Matrix 7GR4202-30
Page 2: ......
Page 14: ...xii...
Page 30: ...XENPAK 10 Gigabit Ethernet 2 4 Network Requirements...
Page 58: ...Completing the Installation 3 28 Installation...
Page 66: ...Last Resort Shutdown Procedure 4 8 Troubleshooting...
Page 74: ...Regulatory Compliance A 8 Specifications...
Page 84: ...Memory Locations and Replacement Procedures B 10 Mode Switch Settings and Installing Options...