Overview of DFE-Diamond Module Shutdown Procedure
Matrix DFE-Platinum Series Module Installation Guide 4-5
Overview of DFE-Diamond Module Shutdown Procedure
The
DFE
‐
Diamond
modules
installed
in
a
Matrix
E7,
Matrix
N3,
or
Matrix
N7
chassis
are
interdependent
and
operate
under
a
single
IP
address
as
a
single,
distributed
switch
system
(hardware,
databases,
and
persistent
storage).
In
this
operating
environment,
the
DFE
‐
Diamond
module
must
shut
down
in
an
orderly
fashion
to
ensure
that
the
other
modules
in
the
system
and
other
devices
on
the
network
are
notified
of
the
impending
change.
The
device(s)
can
then
make
intelligent
decisions
and
stabilize
the
network
before
the
change
is
made;
thereby
increasing
network
availability.
You
can
shut
down
a
DFE
‐
Diamond
module
in
an
operating
system
using
the
OFFLINE/RESET
switch
shown
in
Figure 4
‐
2
.
There
are
two
shut
down
procedures.
•
Recommended
shutdown
procedure
(“
Recommended
Shutdown
Procedure
Using
OFFLINE/
RESET
Switch
”
on
page 4
‐
6)
•
Last
resort
shutdown
procedure
(not
recommended)
(“
Last
Resort
Shutdown
Procedure
Using
OFFLINE/RESET
Switch
”
on
page 4
‐
7)
User parameters (IP
address, device and
module name, etc.)
were lost when the
module power was
cycled, the front
panel OFFLINE/
RESET switch was
pressed.
Position of Mode switch (7),
Persistent Data Reset, was
changed sometime before
either cycling power or
pressing the OFFLINE/
RESET switch, causing the
user-entered parameters to
reset to factory default
settings.
Clear Persistent Data that
was set through Local
Management.
The module was moved
either from slot-to-slot or
from chassis-to-chassis.
Reenter the lost parameters as necessary. Refer to
the
Enterasys Matrix DFE-Diamond/Platinum Series
Configuration Guide
for the instructions to configure
the device.
If the problem continues, contact Enterasys Networks
for technical support.
Table 4-2 Troubleshooting Checklist (Continued)
Problem
Possible Cause
Recommended Action
Caution:
Do not remove a DFE-Diamond module
from an operating chassis system before reading
the following information and instructions.
Precaución:
Antes de retirar los módulos DFE-Platinum del chasis en funcionamiento, lea las
siguientes instrucciones y la información suministrada.
Summary of Contents for Enterasys Diamond Distributed Forwarding Engine 7KR4297-02
Page 2: ......
Page 42: ...Completing the Installation 3 20 Installation ...
Page 50: ...Overview of DFE Diamond Module Shutdown Procedure 4 8 Troubleshooting ...
Page 64: ...Index 2 ...