Connecting to the Network
3-10 Installation
Connecting to the Network
Network Connection Using Fiber-Optic Cable
To
connect
the
module
to
the
network,
refer
to
Figure 3
‐
4
and
perform
the
following
steps:
1.
Remove
any
protective
covers
from
the
fiber
‐
optic
ports
and
from
the
ends
of
the
connectors.
2.
Insert
one
end
of
the
SC
cable
connector,
key
side
down,
into
the
SC
port
interface
connector.
Ensure
that
the
appropriate
cable
is
used
for
the
application
of
the
SC
port
connection.
Refer
to
Appendix A
for
the
appropriate
fiber
‐
optic
cable
to
be
used
in
the
installation.
Note:
If the DFE-Diamond module is being installed in a network using Link Aggregation, there are
rules concerning the network cable and port configurations that must be followed for Link
Aggregation to operate properly. Before connecting the cables, refer to the
Enterasys Matrix DFE-
Diamond/Platinum Series Configuration Guide
for the configuration information. For details on how
to obtain manuals, refer to “
Related Documents
” on page xii.
Warning:
The 10 Gigabit interface module uses Class 1 lasers. Do not use optical instruments to
view the laser output. The use of optical instruments to view laser output increases eye hazard.
When viewing the output optical port, power must be removed from the network adapter.
Advertencia:
El Modulo de Interfase de 10 Gigabit usa lásers de clase 1. No se debe usar
instrumentos opticos para ver la potencia laser. El uso de los instrumentos opticos para ver la
potencia laser incrementa el riesgo a los ojos. Cuando vean el puerto de la potencia optica, la
corriente debe ser removida del adaptador de la red.
Warnhinweis:
10 Gigabit Interface Module verwenden Lasertechnologie der Klasse 1. Benutzen
sie keinesfalls optische Hilfsmittel, um die Funktion des Lasers zu überprüfen. Solche Hilfsmittel
erhöhen die Gefahr von Sehschäden. Wenn sie den optischen Port überprüfen möchten stellen Sie
sicher, dass die Komponente von der Spannungsversorgung getrennt ist.
Note:
To prevent contaminating the end of strands in the connectors or ports, leave the protective
covers in place when the connectors or ports are not in use.
Caution:
Do not touch the ends of the fiber-optic strands, and do not let the ends come in contact
with dust, dirt, or other contaminants. Contamination of cable ends causes problems in data
transmissions. If the ends of the fiber-optic strands become contaminated, use a canned duster to
blow the surfaces clean. A cleaning swab saturated with optical-grade isopropyl alcohol may also
be used to clean the ends.
Precaución:
No toque los extremos de los cables de fibra óptica y evite su contacto con el polvo,
la suciedad o con cualquier otro contaminante. Si los extremos de los cables se ensucian, es
posible que la transmisión de datos se vea afectada. Si nota que los extremos de los cables de
fibra óptica se ensucian, utilice aire comprimido para limpiarlos. También puede limpiarlos con un
estropajo embebido en alcohol isopropílico.
Summary of Contents for Enterasys Diamond Distributed Forwarding Engine 7KR4297-02
Page 2: ......
Page 42: ...Completing the Installation 3 20 Installation ...
Page 50: ...Overview of DFE Diamond Module Shutdown Procedure 4 8 Troubleshooting ...
Page 64: ...Index 2 ...