Installing Module into Matrix E7 or Matrix N7 Chassis
3-6 Installation
Example 6 (
Figure 3-1
,
F)
The
module
arrangement
in
this
example
is
similar
to
the
one
shown
in
Figure 3
‐
1
,
E
and
described
in
Example
5.
The
only
difference
is
that
a
DFE
‐
Diamond
bridging
module
is
installed
in
slot
2,
enabling
all
modules
to
communicate
with
each
other.
Rule:
In
this
example,
the
7H4382
‐
49
DFE
‐
Diamond
bridging
module
serves
as
both
the
FTM1
‐
to
‐
FTM2
bridge
and
the
five
‐
to
‐
seven
slot
proxy
bridge.
The
6x3xx
does
not
serve
as
a
proxy
bridge
in
this
configuration
because
the
7H4382
‐
49
is
in
a
slot
with
a
lower
number.
Installing Module into Matrix E7 or Matrix N7 Chassis
To
install
module
into
the
Matrix E7
chassis,
refer
to
“
Backplane
Connections
and
Installation
Rules
”
(page 3
‐
3)
to
familiarize
yourself
with
the
FTM1
and
FTM2
backplane
connections
and
the
module
hardware
installation
rules.
Then
proceed
to
“
Preparation
”
(page 3
‐
6)
to
start
the
installation
process.
To
install
a
DFE
‐
Diamond
module
into
a
Matrix N7
chassis,
proceed
directly
to
“
Preparation
”
(page 3
‐
6)
to
start
the
installation
process.
Preparation
1.
Remove
the
blank
panel
covering
the
slot
in
which
the
module
will
be
installed.
All
other
slots
must
remain
covered
to
ensure
proper
airflow
for
cooling.
(Save
the
blank
plate
in
the
event
you
need
to
remove
the
module.)
2.
Remove
the
module
from
the
shipping
box.
(Save
the
box
and
packing
materials
in
the
event
the
module
needs
to
be
reshipped.)
3.
Locate
the
antistatic
wrist
strap
shipped
with
the
chassis.
Attach
the
antistatic
wrist
strap
to
your
wrist
and
plug
the
cable
from
the
antistatic
wrist
strap
into
the
ESD
grounding
receptacle
at
the
upper
right
corner
of
the
chassis.
4.
Remove
the
module
from
the
plastic
bag.
(Save
the
bag
in
the
event
the
module
must
be
reshipped.)
Observe
all
precautions
to
prevent
damage
from
Electrostatic
Discharge
(ESD).
5.
Examine
the
module
for
damage.
If
any
damage
exists,
DO
NOT
install
the
module.
Immediately
contact
Enterasys
Networks.
Refer
to
“
Getting
Help
”
on
page
xiv.
Caution:
Failure to observe static safety precautions could cause damage to the module. Follow
static safety handling rules and wear the antistatic wrist strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the board or
components can cause damage.
Precaución:
Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad para la
manipulación del producto y no olvide utilizar la pulsera antiestática.
No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto cortante
entra en contacto con la placa o con los componentes, éstos podrían dañarse.