ENSTROM F-28F/280F SERIES MAINTENANCE MANUAL SUPPLEMENT
Rev.
5
MM-24-4
Nov
5/13
Problem Cause
Required Action
Above normal temperatures in
one or more cylinders (CHT).
EDM-700
GEM 603/610
Cracked, missing or open
baffles or doors. Obstruction or
debris in cylinder fins. Cowl
panel doors not secure.
Repair or replace baffles, remove
obstructions, and close panel doors.
Low EGT reading in one
cylinder, continually.
EDM-700
GEM 603/610
Defective or blown exhaust
gasket. Cracked or loose
exhaust system.
Inspect exhaust system and correct
as required.
Intake valve not opening
completely causing low
compression.
Perform a compression check.
Plugged fuel nozzle.
Clean nozzle.
1