Table 21-2. F-28F/280FX Flight Ampere Load Conditions – 28 Volt System
NOTE: The information in this table applies to early production (see paragraph 21-6 NOTE).
ELECTRICAL DEVICE
DAY
NIGHT
A B C D E F G H I J K L
Nav Lights
@ 0.805 amps ea
-
-
-
-
-
3.22 3.22
3.22
3.22
3.22
3.22
3.22
Boost Pump
2.75
2.75
2.75
2.75
2.75
2.75 2.75
2.75
2.75
2.75
2.75
2.75
Long. Trim *
-
2.0
-
2.0
-
-
2.0
-
2.0
-
2.0
-
Lat. Trim *
-
-
2.0
-
2.0
-
-
2.
-
2.0
-
2.0
Radio – Transmit *
-
1.75
1.75
-
-
-
1.75
1.75
-
-
1.75
-
Radio – Receive
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Instrument Cluster
0.07
0.07
0.07
0.07
0.07
0.07 0.07
0.07
0.07
0.07
0.07
0.07
Master Relay
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
Anti-Collision 3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
Panel Lights
-
-
-
-
-
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Forward Landing Light
-
-
-
-
-
-
-
-
-
-
8.93
8.93
Aft Landing Light
-
-
-
-
-
-
-
-
-
-
8.93
8.93
Landing Light Relay
-
-
-
-
-
-
-
-
-
-
0.11
0.11
TOTAL 7.12
11.87
9.12
11.34 15.09
13.34 33.06
29.31