ENSTROM F-28F/280F SERIES MAINTENANCE MANUAL SUPPLEMENT
Rev.
5
MM-24-3
Nov
5/13
Table 24-2. Graphic Engine Monitor Troubleshooting
Problem Cause
Required
Action
Gradual or sudden increase in
EGT of one cylinder.
EDM-700
GEM 603/610
NOTE
GEM 603/610 display will blink when
this occurs.
Partially plugged fuel nozzle,
indicated by no variation in
EGT during magneto check for
that cylinder.
Remove and clean indicated
cylinder nozzle.
Fouled or defective spark plug
or ignition lead.
Perform a magneto check on the
ground. Cylinder that has a faulty
spark plug or ignition lead will drop
on the bar graph and other
cylinders will rise, indicating the top,
bottom plug or lead, with the
problem.
Replace spark plug or lead as
required on indicated cylinder.
Rising EGT readings on all
cylinders.
EDM-700
GEM 603/610
NOTE
GEM 603/610 display will blink when
this occurs.
WARNING
This is a serious indication and can cause abrupt engine failure, if
proper steps are not taken.
Magneto out of time, or faulty.
Perform a magneto check on the
ground. RPM drop on both
magnetos should be excessive.
Check timing. If correct, overhaul or
replace magnetos.
Restriction in fuel system or
servo not flowing correctly.
Check fuel filters and clean.
Perform fuel flow check at nozzles.
Check lines for damage or flex lines
for twist.
Return servo to authorized Bendix
overhaul center.
1
2
3
4 T
CHT
450 %
350
250
1
2
3
4 T
CHT
450 %
350
250
EGT
CHT
*
o 5
o 4
o 3
1 2 3 4
EGT
CHT
*
o 5
o 4
o 3
1 2 3 4
UNCONTROLLED COPY WHEN DOWNLOADED OR PRINTED
Visit www.enstromhelicopter.com for instructions to order an original manual and to register for email notification of updates.