54
CONTROL2, CONTROL3, CONTROL4 [ON/OFF]
This command turns the selected control output on or off, e.g. car heating. If the control output in question
is not configured as manually controllable, the system sends the reply message
”Function unavailable”
.
DELAY [LENGTH OF DELAY]
This command sets the burglar alarm exit delay, during which it is possible exit the premises without
triggering the burglar alarm. The delay can be set between 0 – 15 min. The entry delay is 1 minute. E.g. The
user sets the burglar alarm delay to 10 min »
DELAY 10
TEMPOUT [DESIRED ALARM LIMIT]
This command changes the outside temperature alarm limit. The alarm li-
mit can be set between -30 – +50 °C. E.g. the user sets the outside tempera-
ture alarm limit to -10 °C »
TEMPOUT -10
TEMPIN [DESIRED ALARM LIMIT]
This command changes the inside temperature alarm limit. The alarm limit
can be set between -30 – +50 °C. E.g. the user sets the inside temperature
alarm limit to 5 °C »
TEMPIN 5
Control Commands
HOME
The command sets the eSmart and the premises to the
Home
mode.
HOME-SAFE
The command sets the eSmart and the premises to the
Safe at home
mode.
AWAY
The command sets the eSmart and the premises to the
Away
mode. A call
to the system has the same function.
AWAY-LONG
The command sets the eSmart and the premises to the
Away long
mode.
ACK
The command
ACK
acknowledges all alarms and reactivates the alarm in-
puts. A humidity alarm cannot be acknowledged by a text message.
SETBACK [DESIRED TEMPERATURE SETBACK]
This command changes the SMART temperature setback for the Ensto ECO-
16FR thermostat. If the SMART function is unavailable, the device sends the
reply message
”Function unavailable”.
E.g. the user reduces the tempera-
ture of the Away mode by 10 °C »
SETBACK 10
SMS [TEXT]
This command relays the text message to all confirmed numbers in the user
catalogue. E.g. a user saved in user catalogue position 1 informs all other
users that he or she has arrived »
SMS I AM HERE NOW
Status and History Queries
STATUS
The command
STATUS
provides a reply message indicating the current sta-
tus of the premises, outputs and alarms.
TEMPOUT -10
Outside tempera-
ture alarm limit set
to -10.0 degrees
HOME
State set: Home
ACK
All alarms checked
SETBACK 10
Smart setback set
to10 degrees
STATUS
State: Away
Temp in: 21,3C
Temp out: 8,7C
General: no alarm
Humidity: no alarm