background image

RLV450

      69-2201EF-03                    2009-08-04                    1/4

LP

 appears only for the first two minutes when the thermostat is without power. This

can occur during a power outage or when the thermal protection device inside the base-
board heater is opened.

This programmable thermostat can be used to control an electric
heating system such as an electric baseboard heater, a radiant ceil-
ing, a radiant floor, a convector or a fan-forced heater.

The thermostat cannot be used with:

a resistive load over 16.7 A

a resistive load under 2 A

a system driven by a contactor or relay (inductive load)

a central heating system

SUPPLIED PARTS:

One (1) thermostat

Two (2) 6-32 screws

Two (2) solderless connectors

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK. THE INSTAL-
LATION MUST BE PERFORMED BY AN ELECTRICIAN.

All cables and connections must conform to the local electrical
code. 

Special CO/ALR solderless connectors must be used when con-
necting with aluminum conductors.

Install the thermostat onto an electrical box.

Install the thermostat about 1.5 m (5 feet) high, on an inside wall
facing the heater.

Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight. 

Do not install the thermostat on a wall that conceals chimney or
stove pipes.

The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.

NOTE: 

Always keep the thermostat's vents clean and unobstructed.

n

o

Connect the thermostat wires to the line wires and to the load 
wires using solderless connectors for copper wires.

p

Push any excess wire back into the electrical box. 

NOTE: 

If necessary, before re-installing the front component, config-

ure the thermostat (see section 3).

q

Return power to heating system.

n

Description

1.

o

Installation

2.

Select the mode 
of operation

Set the time

Time and day

Temperature

Indicates the current 
mode of operation

Skip a period

Program the schedule

Temperature 
preset icon

Temperature 
adjustment 
buttons

Temperature 
preset buttons

Indicates the 
heating power

Indicates the current 
period (appears in 
automatic mode only)

Indicates that the 
temperature setpoint 
is displayed

Set the day

Indicates that the 
thermostat is configured 
for a fan-forced heater

Indicates that the ther-
mostat is without power *

Indicates that the 
settings are locked

2-wire installation

4-wire installation

RLV450

User Guide

Programmable Thermostat

400-106-021-D_69-2201EF-03 (RLV450 Honeywell TH106B) ENG.fm  Page 1  Tuesday, August 4, 2009  4:33 PM

Summary of Contents for RLV450

Page 1: ...case or an air outlet dead air spots such as behind a door or direct sunlight Do not install the thermostat on a wall that conceals chimney or stove pipes The thermostat wires are not polarized either wire can be con nected to the load or to the power supply NOTE Always keep the thermostat s vents clean and unobstructed n o Connect the thermostat wires to the line wires and to the load wires using...

Page 2: ...ure using the or button Press and hold the appropriate button or for approximately 3 sec onds until the corresponding icon is displayed To store the Vacation temperature Set the desired temperature using the or button Press and hold both and buttons simultaneously for approximately 3 seconds until the icon is displayed Automatic The temperature is set according to the programmed schedule To place ...

Page 3: ...240 VAC Maximum load 16 7 A resistive only 2000 W 120 VAC 4000 W 240 VAC Display range 0 C to 60 0 C 32 F to 140 F Display resolution 0 5 C 1 F Setpoint range 5 0 C to 30 0 C 40 F to 86 F Setpoint interval 0 5 C 1 F Storage 20 C to 50 C 4 F to 120 F Approval c UL us t Schedule 7 Period Description Setting Wake Leave Return Sleep Period Setting MO TU WE TH FR SA SU 6 00 AM 6 00 AM 6 00 AM 6 00 AM 6...

Page 4: ...BLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEY WELL MAK...

Page 5: ...r comme le haut d un escalier ou une sortie d air des points d air stagnant comme derrière une porte des rayons de soleil Ne pas installer le thermostat sur un mur qui dissimule des con duits d air ou d une cheminée Les fils du thermostat ne sont pas polarisés le sens du branche ment n a donc aucune importance NOTA S assurer que les ouvertures d aération du thermostat soient propres et dégagées n ...

Page 6: ...e bouton de préréglage approprié ou pen dant 3 secondes jusqu à ce que l icône correspondante soit affi chée Pour enregistrer le préréglage de température Vacances Régler la température désirée à l aide du bouton ou Appuyer sur les boutons de préréglages et simultanément pendant 3 secondes jusqu à ce que l icône soit affichée Automatique le thermostat utilise les réglages de l horaire Pour placer ...

Page 7: ...0 W 120 VCA 500 W 240 VCA Charge maximale 16 7 A résistive seulement 2000 W 120 VCA 4000 W 240 VCA Plage d affichage 0 C à 60 0 C 32 F à 140 F Résolution d affichage 0 5 C 1 F Plage de réglage 5 0 C à 30 0 C 40 F à 86 F Intervalle de réglage 0 5 C 1 F Entreposage 20 C à 50 C 4 F à 120 F Homologation c UL us t Horaire 7 Période Description Réglage Réveil Départ Retour Coucher Période Réglage LU MO ...

Page 8: ... DIRECTEMENT OU INDIRECTEMENT D UNE VIOLATION QUELCONQUE D UNE GARANTIE EXPRESSE OU TACITE APPLICABLE AU PRÉSENT PRODUIT NI DE TOUTE AUTRE DÉFECTUOSITÉ DU PRÉSENT PRODUIT Certaines provinces ne permettent pas l exclusion ou la restriction des dommages indirects et par conséquent la présente restriction peut ne pas s appliquer LA PRÉSENTE GARANTIE TIENT LIEU DE TOUTES LES AUTRES GARANTIES EXPRESSES...