51
Control settings
Siren
is the default function of relay 2,
Manual control
is the default fun-
ction of relays 3 and 4. The following functions are available as relay func-
tions:
Siren, SMART -setback, Manual control, Away, Outdoor lighting,
Car heating, Water valve
or
Temperature control
. The control settings are
entered in
Settings/Parametrization/Control settings
.
The installer code 6143 is needed for settings that affect the system func-
tions. The control settings will be specified and the required connections
installed by the electrician. Note! Do not change these settings unless the
connections have been changed accordingly!
If water valve control is selected, the relay will activate and the water supply
valve will close when the
Away long
mode is selected or a humidity alarm is
triggered. Investigate the cause of a humidity alarm before acknowledging
it.
Change code
Enter the current code. If the code is incorrect, the operating panel asks the
code once more. When you have entered the correct code, the device asks
the new code twice and saves the new code.
Remove data files
When you select
”Remove data files”
, all the data stored in the operating
panel will be deleted. If the measuring device is not reset, the data for the
past 2 weeks will be retransferred to the operating panel memory card. De-
leted files cannot be restored.
Alarm settings
Turn the alarms on / off. The operating panel alarm sound is enabled by
pushing an activated alarm again.
System reset
The factory settings are restored:
•
System is in
Home
mode.
•
All alarms are disabled
•
Smart setback is 5 °C
•
Outside and inside temperature alarm limit +10 °C
•
Relay 2 is configured to control the
Siren
, relays 3 and 4
Manual control
•
Car heating settings are reset
•
Control of outdoor lighting is reset
•
Optional settings are reset
Exit delay
Set the burglar alarm exit delay, during which it is possible to exit the pre-
mises without triggering the burglar alarm. The delay can be set between
0 – 15 min. The entry delay is 1 minute.
Local Button Operation
A button or code switch for changing the premises mode can be connected to the eSmart. The local
button is a spring-return closing contact switch, which activates the functions based on closing contact
information.