USER MANUAL
STM 550X / EMSIX
–
ENOCEAN MULTI-SENSOR
© 2020 EnOcean | www.enocean.com F-710-017, V1.0
STM 550x / EMSIx User Manual | v1.0 | February 2020 | Page 43/79
7.4.6
Read command
The READ command requires a start page address, and returns the 16 bytes of four
NFC tag pages (where each page is 4 byte in size).
For example, if the specified address is
03h
then pages
03h
,
04h
,
05h
,
06h
are returned. Spe-
cial conditions apply if the READ command address is near the end of the accessible
memory area.
Figure 26 below shows the read command sequence.
Figure 26
–
NFC read command sequence
7.4.7
Write command
The WRITE command requires a start page address and returns writes 4 bytes of data into
that page.
Figure 27 below shows the read command sequence.
Figure 27
–
NFC write command sequence