Cut the leads to length, dismantle them and
connect
L1
and
N
to the connection terminals
of the power supply as shown.
IMPORTANT
Before starting with the installation, make sure that the
power supply line is dead (de-energized).
L1
N
35 mm
6 mm
6 mm
150 mm
L1
N
Loosen the screw in the cover of the power
supply housing and remove the cover (on the
side where the connections are located).
IMPORTANT
Keep the cover and the screw in a safe place as you
will require it later.
REMOVE POWER SUPPLY COVER
1.
B
A
When the system is installed with permanent
power supply, the internal power supply socket
has to be removed.
Loosen the screws at the end stop and move
the end stop to the centre of the system.
IMPORTANT
Do not remove or screw down the end stop.
MOVE END STOP
B
A
1
2
Lay the grounding line through the housing
of the operator as shown in the picture and
connect it to the grounding terminal (PE).
EARTH CONNECTION
5
Carefully open the cover of the control unit
housing by levering it out with the tip of a flat-
bladed screwdriver.
Relax the screws of the connection terminals
and remove the internal shockproof socket.
REMOVE INTERNAL SOCKET
B
A
3
LIVE & NEUTRAL CONNECTIONS
4
How to hard-wire a permanent power supply to your Motus powered
Enigma pocket door system.
Hardwired power supply
2 9
M O T U S N F R V › I N S T A L L A T I O N G U I D E
|
H A R D W I R E D P O W E R S U P P LY