Another application is to tap the Delay time via CC #54.
To tap the delay time, the time between two sent values with CC #54 is measured. As an example,
the assignment via an external MIDI foot controller can look like this:
MIDI footcontroller “A” sends via pushing button “X” (Momentary) when pressed CC #54, value 127,
when pressed again it sends again CC # 54, value 127. The time between the operations indicates
the delay time.
The following table lists amp functions and their assigned MIDI controller numbers.
USB
Connect the amp to a computer to drag and drop your impulse response files.
Impulse responses will be stored in alphabetical sequence to the slots 4 to 8.
This is how it works:
1. Connect your the amp via a USB-B cable with your computer.
2. Power the amp up and wait until the internal memory "ENGL" is recognized and ready.
3. Now you can drag and drop the desired IR to the amps internal memory.
4. When done, [Safely Remove Hardware] and disconnect the amp from the computer.
5. “Reboot” the amp (turn the amp off, wait about 10 seconds and turn it on again).
6. Now the loaded IR is ready to use.
Supported IR Files:
Files in
mono
up to a maximum size of
128kB / 96kHz (1 second @ 48kHz; 500ms @ 96kHz)
.
The saved files are automatically assigned to the IR selector switch (4 to 8) in alphanumeric order.
If the files are outside of these specifications, they cannot be read and processed.