4.

 

Technical Specification 

 

Enforcer 32-WE Mains Inputs 

European rated 
voltage 

230V AC -15/+10% 

European rated 
current 

63mA 

Capable operating 
voltage 

90 - 264V AC 

Current 

22 - 75 mA 

Rated Frequency 

50 / 60Hz 

Input Fuse Rating 

T 2A (non replaceable) 

PSU Type 

Radio Frequency 

868MHz, FM Transceiver 
Narrow Band 

 

Physical Dims 

220 x 160 x 50mm 

Weight 1025g 

 

Environmental  

 

Operating Temp 

-10°C to +40°C 

Storage Temp 

-20°C to +60°C 

 

I/O Board (If Connected) 

Belgium installations: To guarantee compliance 
with the standard T014A no load shall be 
connected to the I/O board. 

Output Voltage 

9-16VDC (12V nom.) 

Max Current Output 

0.07A allowed 

PGM/BELL/STB 
Outputs 

250mA Continuous 
Load 

BELL / Aux Fuses 

500mA, Quick Blow 

 

Electrical (Keyfob, PIR & Contact) 

Operating Voltage 

3.0V nominal 

Current 
(Communicating) 

Consumption:  

40-80-mA 250mA 

Continuous 

Load 

Comms Time 

40mS + 40ms 

Battery Type (KF) 

BATT-CR1/3N(KF4 
MK2) 

Battery Type (PIR) 

BATT-CR123A 

Battery Type (UT) 

BATT-CR2 

 
 
 
 
 
 
 
 

 
 

 

 

 
 

 

Environment: All Devices 

Nominal operating 
temperature 

-10°C to +50°C 

Certified operating 
temperature 

-10°C to +40°C 

Storage temp. 

-40°C to +80°C 

Enforcer Battery 

Output instant voltage 

12.71V (with no mains 
and battery fully 
charged) 

Peak to peak ripple 
voltage 

10mVpk 

Battery low voltage 
value 

8.9V 

Type 

NiMH 8 cell 2200mAh 
rechargeable battery 

CIE current when 
operating on battery 
backup 

90mA 

Systems Analysis: Inputs 

On Board 

32 Wireless 

I/O Board 

2 Wired 

If wired connection is used one zone shall be 
program as “Fault”. 

Systems Analysis: Outputs 

I/O Board 

3 Wired 

Bells 2 

Wireless 

Output Module 

1 x 16 Relays 

System Analysis: Additional Devices 

Keypads 

Up to 3  

Readers 

Up to 3 

Bell Boxes 

1  

EN 50131 Grade 2: Certified devices  

Enforcer 32-WE with input/output board 

KX10DP-WE KX12DQ-WE 
MC1-WE MC2-WE 
KF4-WE DELTABELL-WE 
KX12DT-WE DIGI-1200 
KX10DTP-WE KX25LR-WE 
KX15DC-WE MC1MINI-WE 
 

 

 

 

 

 

Summary of Contents for RINS1708-3

Page 1: ...s a 100 dBA siren please be aware of this during installation EN50131 1 2006 A1 2009 EN50131 3 2009 EN50131 6 2008 EN50131 5 3 2005 A1 2008 Security Grade 2 Environmental Class II Software Version 10...

Page 2: ...Important Installation Notes 6 4 Technical Specification 7 5 Installation Guide 8 5 1 Wiring Peripherals to the RS485 Bus 9 5 2 Entry Control with the Internal Tag Reader 13 5 3 Entry Control with the...

Page 3: ...put Expanders Total Inputs Wireless Wired 66 On board outputs 3 User Automation Outputs 19 Outputs max 34 16 x 1 x Wired Output Exp 12 x 4 x Wired Input Exp 3 x Keypads Readers User Codes and Tags 75...

Page 4: ...ing the front of the Enforcer 32 WE as modems I O boards etc may be connected to the front 3 Rotate the front of the Enforcer 32 WE 180 degrees and hang it on the opening screws if required 3 1 Mains...

Page 5: ...if the Enforcer 32 WE is installed on an uneven surface 5 If an I O board is installed then this space is used to install it See page 9 3 3 Inside of the Enforcer 32 WE Front 1 RS232 connection for Up...

Page 6: ...cian Ensure that a readily accessible disconnect device is incorporated in the premises installation wiring and is provided external to the equipment with a contact separation of at least 3 0mm and co...

Page 7: ...A Continuous Load Comms Time 40mS 40ms Battery Type KF BATT CR1 3N KF4 MK2 Battery Type PIR BATT CR123A Battery Type UT BATT CR2 Environment All Devices Nominal operating temperature 10 C to 50 C Cert...

Page 8: ...nciples NOTE 1 No alarm system cable should be run with other cables carrying AC or digital signals NOTE 2 The cables should be protected by the use of grommets where appropriate NOTE For greater than...

Page 9: ...4 The maximum devices the I O board can have on the RS485 bus are as follows 4 x Input Expanders PCX RIX8i PCX RIX8 PCX RIX8 PSU 1 x Output Expander PCX ROX8R8T or PCX ROX16R PSU 4 x Keypads Readers s...

Page 10: ...cess control entry control please refer to page 13 5 1 4 Wiring External Readers If an additional external reader is connected this will need to be assigned in the programming of Assign Keypads Reader...

Page 11: ...cuit of the bell box Note that the input must be programmed as tamper The resistor value is 1K as shown in the diagram above IMPORTANT NOTE THE BELL BOX CONNECTED WILL NEED TO BE IN SCB self contained...

Page 12: ...using a PCX RIX8 PSU the D2 MUST NOT be connected RIX Address 0 Inputs 35 42 RIX Address 1 Inputs 43 50 RIX Address 2 Inputs 51 58 RIX Address 3 Inputs 59 66 5 1 8 Connecting an Output Expander 1 x Re...

Page 13: ...Page 13 5 2 Entry Control with the Internal Tag Reader 5 2 1 Connecting the Push to Exit Button Entry Control 5 2 2 Connecting the Mag Lock Control Entry Control...

Page 14: ...control panel and the door will lock The system will set after the final door is closed exit time expires 5 2 4 Disarming with Entry Control Action Visual Sequence Present a valid tag to the reader a...

Page 15: ...Page 15 5 3 Entry Control with the External Tag Reader 5 3 1 Connecting the Push to Exit Button Entry Control 5 3 2 Connecting the Mag Lock Control Entry Control...

Page 16: ...ill start on the control panel The RED LED will illuminate when the system has armed and after a few seconds the LED will extinguish 5 3 4 Disarming with Entry Control Action Visual Sequence Present a...

Page 17: ...tings have been entered for your network see Network Setup page 26 On InSite UDL software from a PC First of all once the software has opened go to the configuration tab and then select modem settings...

Page 18: ...Scroll the menu X button until the Options Up Downloading 3 Choose Modem in the Download by option On InSite UDL software from a PC 1 To setup the COM port associated to modem open the software click...

Page 19: ...a service or not as listed below Some networks provide the data channel as a standard service with pay as you go and contract SIM cards Some networks have to enable the data channel separately Some ne...

Page 20: ...o communicate over a Local Area Network to either InSite Pyronix Cloud or to an ARC NOTE The product has been approved as supplied If the communications module is replaced with a different model besid...

Page 21: ...nicate either via contact ID Fast Format SIA or SMS texts via a telephone line It will also enable remote uploading downloading Before making these connections all power must be disconnected from the...

Page 22: ...or Disarmed Mode Unset State may be relevant to a specific area Personal Attack PA Hold Up HU Bypass Inhibit Unused Isolated Bell External Sounder SAB External Warning Device self powered is assumed...