5.1.3
Wiring Internal Readers
Up to 3 readers can be connected to the Enforcer 32-WE. Each reader needs to be
addressed as described below. These will also need assigning in the Engineer function '‘Assign
Keypads / Readers’.
Addressing at the Reader
Address 1 = SWITCH 1 ON.
Address 2 = SWITCH 2 ON.
Address 3 = SWITCH 1: ON, SWITCH 2: ON.
NOTE
: If using the PCX-PROX/INT as access control/entry control please refer to page: 13.
5.1.4
Wiring External Readers
If an additional external reader is connected, this will need to be assigned in the programming of
‘Assign Keypads/ Readers’. Each reader will also need to be addressed individually via connecting
certain wires to ground.
Addressing at the Reader
Address 1: Brown, Orange to D1- (Ground)
Address 2: Brown, Green to D1- (Ground)
Address 3: Brown to D1- (Ground)
NOTE
: If using the PCX-PROX/E as access control/entry control please refer to page: 15.
PCX-PROX/INT
PCX-PROX/E
Black (D1-)
Red (D2+)
Yellow (D3)
Blue (D4)