1 Sitting
Small changes in wind speed and wind direction can have a dramatic effect on power produc-
tion. In general, the higher the tower, the greater the wind speed and ultimately power
production. Therefore, the siting of yourwind turbine should be carefullyconsideredEach
installation is different and is often a compromise among tower height, distance from the
battery bank, local zoning requirements and obstacles such as buildings and trees.
Specific requirements about installation and sitting of wind turbine are as follows:
2.1 The minimum recommended tower height is 8m on open ground or 5m above nearby
obstructions. there are no obstacles within 100 meters as far as possible:
2.2 If install two wind turbines on one area, the distance between them is 8-10 times of rotor
diameter. Try to locate the wind turbine in the “cleanest” turbulent free air as possible. Turbu-
lence will reduce the efficiency ofthe wind turbine and may accelerate wear on rotating
components.
2.3 Less natural disaster places are preferred.
2.4 Safety must be the primary concern when selecting the mounting location. Even if install-
ing the wind turbine in a less than ideal location. don‘t attempt to mount the turbine while
blades are spinning.
1
2 Technical specification
Rated speed (m/s)
Start-up speed (m/s)
Cut-in speed (m/s)
1.5
2.0
GE-600-24
GE-1200-48
2.0
2.5
Rated voltage (DC)
24V
48V
Rated output (W)
600
1200
Rotor diameter (m)
1.7
2.0
12
Blades
5
Rated rotation speed
650
Heavy wind protection Dump load - electromagnetic break
Certificate
CE - ISO9001 - RoHS
Summary of Contents for GE-600-24
Page 1: ...GE 600 24 USER MANUAL...