10
Battery overcharge recovery
Battery over charge voltage
Load 1 & 2 discharge voltage
Load 1 & 2 discharge recovery
28V
29V
21.6V
24.5V
Weight (Kg)
Size - LxWxH (mm)
Working temperature
Working humidity
1.4
176 x 135 x 56
-40°C ~ +45°C
0 ~ 95% R.H. (not gel)
Working height
The hight altitude of 3.000 m
Protection class
IP22
8. terminals
7. LED display
9. safety plate open
indicator
10. safety plate
LED display all of controller setting data.
Connected the outside wind generator, solar panels, street lamp
and batteries.
Safety plate burned open circuit then indicates keep bright state.
In the case charger over-current load over-current etc, it burned.
9.2 Controller parameters and specifications
The wind generator rated power
Battery rated voltage
Input current range
Max input power of the wind
generator
600W
24V
0~35A
660W
Max power of solar charge
Intelligent stop system start
voltage
Battery over discharge protection
voltage
Battery over discharge recovery
voltage
600W
≥ 29V
21.6V
24.6V
1 & 2 output rated current
10A / 10A
9.3 Electrical parameters of the control
Summary of Contents for GE-600-24