Questions and answers P.
341 of 349
Questions and answers
ErrorCode Eventlog
Error code
explanation
ERR_PROC_OBJECT
An object (a function) could not be processed. This can have
several, function-specific causes. Please pay attention to more
error messages.
ERR_PROC_OBJECT_MSG_OUT
An output object could not be processed. This can have the
following functions relate to: 1 write access to the KNX bus 1.1
settime 1.2 setdate 1.3 settimedate 1.4 write 1.5 read 1.6 write
response 1.7 scene 1.8 store scene 1.9 callscene 1:10
eibtelegramm 2 Network Functions 2.1 closetcp 2.2 ConnectTCP
2.3 ping 2.4 resolve 2.5 send html mail 2.6 sendmail 2.7 sendtcp
2.8 sendtcparray 2.9 sendudp 2:10 sendudparray 3 RS232
interface 3.1 resetrs232 3.2 sendrs232 4 VPN Server 4.1
closevpnuser openvpnuser 4.2 4.3 4.4 startvpn stopvpn Please
check if an appropriate connection exists
ERR_PROC_REPETITIONS
An endless loop has been detected. Processing was therefore
canceled.
ERR_POW_OF_NEG_BASE
During the processing of a function pow an error was detected,
the base is negative. The calculation is thereforenot processed.
ERR_LOG_OF_NON_POS_BASE_OR_ARG
During the processing of the log function, an error has been
recognized that the base or the argument is not positive. The
calculation is therefore not processed.
ERR_SQRT_OF_NON_POS_ARG
The error is sqrt When processing function detected that the
argument is negative. The calculation is therefore carried out.
ERR_ASIN_OF_ARG_OUT_OF_RANGE
The error was asin When processing function detected that the
argument outside the interval [-1; +1] is. The calculation is
therefore carried out.
ERR_ACOS_OF_ARG_OUT_OF_RANGE
When processing the acos function the error was detected that
the argument outside the interval [-1; +1] is. The calculation is
therefore carried out.
ERR_DIVISION_BY_ZERO
During processing of a division of the error has been detected,
the divisor is equal to 0. The calculation is therefore carried out.
ERR_EIBNET_IP_SETSOCKOPT_0
It is an error in the preparation of the compound occurred to a
KNXnet / IP interface.
ERR_EIBNET_IP_SETSOCKOPT_1
s.a.
ERR_EIBNET_IP_SETSOCKOPT_2
s.a.
ERR_EIBNET_IP_SENDTO_0
An error has occurred while sending a message to a KNXnet / IP
interface.
ERR_EIBNET_IP_SENDTO_1
s.a.
ERR_EIBNET_IP_SENDTO_2
s.a.
ERR_EIBNET_IP_SENDTO_3
s.a.
ERR_EIBNET_IP_SENDTO_4
s.a.
ERR_EIBNET_IP_SENDTO_5
s.a.
ERR_EIBNET_IP_TIMEOUT_SEARCH
There could be found no KNXnet / IP interface. Please check
whether an operational KNXnet / IP interface is connected to the
same network as the EibPC.
ERR_EIBNET_IP_DISCONNECT_REQUEST_IN
The connection between EibPC and KNXnet / IP interface has
been disconnected.
ERR_EIBNET_IP_DISCONNECT_REQUEST_OUT
s.a.
ERR_EIBNET_IP_TIMEOUT_CONNECTIONSTATE_REQUEST s.a.
ERR_EIBNET_IP_E_CONNECTION_ID
s.a.
ERR_EIBNET_IP_E_DATA_CONNECTION
The KNXnet / IP interface has detected an error connecting to
the EibPC.
ERR_EIBNET_IP_E_KNX_CONNECTION
The KNXnet / IP interface has detected an error in the
connection to the KNX bus.