![Enerpac ZE3 series Instruction Sheet Download Page 9](http://html1.mh-extra.com/html/enerpac/ze3-series/ze3-series_instruction-sheet_2411367009.webp)
9
operated. Toggle between hours and cycles by pushing either
the Down or Up Arrow button. Step forward by pressing the
Menu button. See QRC step #6.
G. "Local" Menu
(See Screen 14.) This screen allows the operator to toggle the Local
mode ON or OFF, default is OFF. With Local mode ON, the shroud
buttons replace the pendant buttons as the method to operate the
pump (NOTE: The word "Local" replaces "OK" on the "Normal
Operations" display and the pendant buttons become deactivated).
Local mode will provide operation of the pump if the pendant or
pendant cord is damaged. Toggle Local mode ON or OFF by
pressing the Down (Up) Arrow button. Save setting and step
forward by pressing the Menu button. See QRC step #7.
H. "Language" Menu
With a language shown on the text display the operator can change
the display language by pressing the Down (Up) Arrow buttons. Save
setting and step forward by pressing the Menu button. See QRC
step #8.
I. "Diagnose"
Menu
(not used)
Fan
Pendant DOWN ARROW button
Pendant UP ARROW button
Pendant ON/OFF button
(See Screen 16.) This screen allows the operator to troubleshoot
several pendant problems by displaying if the microprocessor has
received a signal from the pendant button. No signal indicates the
problem is most likely with the pendant keypad or pendant cord.
Use Local mode to operate pump until problem can be corrected.
See QRC step #9.
(See Screen 17.) Diagnose screen with Pendant motor button
pushed.
(See Screen 18.) Diagnose screen with Pendant Advance button pushed.
(See Screen 19.) Diagnose screen with Pendant Retract button pushed.
6.5 LCD Hidden Menus - available when the optional
pressure transducer is installed
A. “AUTOMODE”
Menu
(See Screen 20.) This screen allows the operator to toggle Off
and On the pump’s ability to automatically control motor /
electric valve functions. To access this menu, go to the “UNITS”
menu, then press and hold the ON/OFF button in for 7 seconds,
ENTRY CODE will appear. Then press and hold ON/OFF and Up-
Arrow buttons for 7 seconds.
OFF - the pump displays pressure as a simple pressure gauge,
no additional actions will be performed.
ON – the pump will de-energize or energize the motor / electric
valve when the hydraulic pressure reaches operator defined
Screen 17
Press
SET
ENGLISH
Screen 15
Screen 14
SET
LOCAL
OFF
Screen 16
SET
DIAGNOSE
00001
PSI
DIAGNOSE
10001
PSI
DIAGNOSE
01001
PSI
Screen 18
DIAGNOSE
00101
PSI
Press
Screen 19
Press
Screen 14
Screen 20
SET
AUTOMODE
OFF
Summary of Contents for ZE3 series