CAUTION:
For optimized pump performance it is
recommended NOT to run the pump at Low Voltage
condition.
6.4 LCD Menus
(Also refer to Table 1, Quick Reference Chart (QRC) located after
Section 9.0)
A. Normal Operation
(See Screen 8.) LCD screen on a Z-class pump. CB has booted
successfully (OK); the pressure reading is 0 psi. Enter into the
menus by pressing the Menu button. See QRC step #1.
B. "Units" Menu
(See Screen 9.) This screen allows the operator to set the unit of
pressure-measurement by pressing the Down (Up) Arrow
buttons. PSI, BAR, Mpa are the options with PSI being the
default. Save setting and step forward by pressing the Menu
button. See QRC step #2.
C. "Motor" Menu
(See Screen 10.) This screen allows the operator to read the
number of hours (On/Off cycles) the motor has been operated.
Toggle between hours and cycles by pushing either the Down
or Up Arrow button. Step forward by pressing the Menu button.
See QRC step #3.
_________________________________________________________
General note for all hour and cycle displays:
HOURS DISPLAYED
- up to 9999.9 the display will show decimal hours
- between 10,000 - 99,999 whole hours will be displayed
(decimal "." is not displayed).
- over 99,999 hours the meter starts over at 0.0 reading
decimal hours
CYCLES DISPLAYED
- over 99,999 cycles the meter starts over at 0
_________________________________________________________
D. "Low Volt" Menu
(See Screen 11.) This screen allows the operator to read the
number of hours the pump has been operated in low-voltage
condition. Step forward by pressing the Menu button. See QRC
step #4.
E. "Advance" Menu
(See Screen 12.) This screen allows the operator to read the number
of hours (On/Off cycles) the Advance solenoid has been operated.
Toggle between hours and cycles by pushing either the Down or Up
Arrow buttons. Step forward by pressing the Menu button. See
QRC step #5.
F. "Retract" Menu
(See Screen 13.) This screen allows the operator to read the
number of hours (On/Off cycles) the Retract solenoid has been
Screen 8
OK
0
PSI
8
Screen 10
MOTOR
4.8
HOURS
CYCLES
SET
UNITS
Screen 9
PSI
MPa
BAR
Screen 13
RETRACT
334
HOURS
CYCLES
Screen 12
Screen 11
LOW VOLT
.0
HOURS
CYCLES
ADVANCE
188
HOURS
CYCLES