EG-SMS PROGRAMMABLE POWER OUTLET STRIP
WITH GSM INTERFACE
All brands and logos are registered trademarks of their respective owners
Tap sensor info lines or “Device setup” from menu (Figure 12) for
configuring sensors and device time. (Figure 13)
Note: If EG-SMS is powered off for some hours (more than 2 hours)
internal timer can be timed out. Then device time shall be set again.
LOCKER is normally-closed contact, WATER is normally-open
contact. The device sends you an alert SMS if temperature has got out
the range, or any sensor has got alarmed (LOCKER open or WATER
closed). Date and time setup is required for the hardware programmable
schedule usage. Temperature limits can be set from -50 to +120 degree
C. (Figures 14,15)
Note: program warns you every time before sending SMS message
(excepting pop-up “Get status” menu). (Figure 16). Remember about
money balance of device’s SIM card (usually SIM card’s balance can be
controlled via your mobile operator web-site).
You can download device settings from by using “Download
settings” menu. (Figure 17)
For resetting alarms from all sensors use “Reset alarmed sensors”
menu (Figure 17).
Long tap of a socket (Figure 10) opens the time schedule dialogue of
the socket. Each socket can execute up to 10 scheduled switches on/off.
(Figure 18).
A switching event can be executed once or periodically.(Figure 19)
For periodic events loop period of days/hours/minutes/seconds shall
be set. (Figures 20,21)