11
EG-SMS PROGRAMMABLE POWER OUTLET STRIP
WITH GSM INTERFACE
All brands and logos are registered trademarks of their respective owners
The manageable sockets of EG-SMS can be programmed to be
on or off. The current status of each manageable socket is represented
by the corresponding indicator which will be lit if socket has power to it.
If the
Main rocker switch
(Figure #1) is turned off then the
manageable sockets cannot be switched on via either GSM or the
hardware schedule.
As soon as you turn the
Main rocker switch (Z)
on then it is be
able to turn the manageable sockets on and off.
Password button
(Figure #2) When this button is pressed, the
new password, which is received in incoming password SMS, will be
applied. See Clause.3.3 or 5 for setting the password
To protect the connected devices from possible high current
and short circuit EG-SMS is equipped with the automatic circuit breaker,
which is embedded in the
Main rocker switch.
When EG-SMS is powered off or disconnected from power
mains it stays connected the GSM network and accessible via SMS for
some hours ( 2-4 hours ) because of LiIon battery. After the battery is
discharged it becomes inaccessible until it is powered on. When battery
is discharged, the device shall be kept in power on state for some 12
hours for for full restore the battery charge.
NOTE:
If the total power consumption (or peak power) of the
devices, connected to EG-SMS exceeds 2200 Watts, the circuit breaker
may power EG-SMS off. In this case, please, remove the excessive load