16
EG-SMS PROGRAMMABLE POWER OUTLET STRIP
WITH GSM INTERFACE
All brands and logos are registered trademarks of their respective owners
For clearing all alarms send SMS to the device:
PASSWORD03
Response SMS:
ALARMS CLEARED
4.3 Control socket autonomously by WATER, LOCKER,
TEMPERATURE sensors
First, enable the corresponding sensors and set temperature limits,
as it is written in p4.2.
For controlling the socket by sensors use the following command.
It ties socket to sensors and controls it according to the current
status of the sensor or temperature range. The device doesn’t issue any
alarm SMS, when sensor changes it’s state or temperature is out of limits.
This temperature limits are independent from limits in alarm section.
PASSWORD500A0B0CSLLLSHHH0F0G0H0I
A – Socket number , 0 for Socket 1, 1 for Socket 2 , etc.
B – Temperature sensor is controlling the socket. 1 – yes, 0 - no
C – Socket control, when temperature is within the limits.
1 – Socket ON, 0 – Socket OFF