EG-SMS PROGRAMMABLE POWER OUTLET STRIP
WITH GSM INTERFACE
All brands and logos are registered trademarks of their respective owners
C-WATER sensor
D-Response SMS for all commands, except alarm and password
response commands
Value: 1-Enable, 0-Disable
SLLL– low temperature limit, in degrees C. S is sign – or +.
Example: -001 equals to -1 degree C.
SHHH – high temperature limit, in degrees C
TTTTTTTT –inversion timestamp, hexadecimal coded, in seconds.
It’s time since Jan,1 1970, 00:00:00. Example: 5179191D equals to Thu,
25 Apr 2013 11:52:44 GMT. ( Time stamp is optional for input ).
ТTTTTTTT=1D197951
Note: If EG-SMS is powered off for some hours (more than 2 hours)
internal timer can be timed out. Then it shall be set again by this SMS.
When the corresponding sensor is enabled, it issues alarm
For Temperature sensor alarm is issued once when temperature
exceeds high limit or below low limit. For LOCKER sensor alarm is issued
once, when contact is opened. For WATER sensor alarm is issued once,
when contact is closed.
Alarm SMS (example):
STATUS SOCKETS: ON OFF OFF ON, LOCKER ALARM, WATER
ALARM, TEMP +14C ALARM, NO POWER