46
0002-40-38085 Rev 01 © Enduro Pipeline Services, Inc. All Rights Reserved.
2.9.4.8.
Remove the Push Poles by using evenly distributed force straight back from where the DdL™ Caliper Tool was
positioned. (
refer to 2.9.3.8. Table
)
2.9.4.8.1.
Doing so, will help prevent any undue damage to the DdL™ Caliper Tool by the Push Poles.
2.9.3.8. Table
2.9.4.9.
Remove any remaining loading equipment from the area.
2.9.4.10.
Secure the pipeline to allow pressure to be brought back up.
2.9.4.10.1.
NOTICE
:
Pressure MUST be brought back up slowly so that the DdL™ Caliper Tool does not prematurely
move.
2.9.4.11.
Once the trap is equalized, continue with procedures to properly launch the DdL™ Caliper Tool.
2.9.4.12.
Verify that the DdL™ Caliper Tool has launched.