Electrical connection
Smart System for Aquacultures SSP200B
24
Hauser
6.5.4
Connecting the supply voltage for the Modbus Edge Device, 24
V DC
1
1
2
3
2 3
0V 24V
PE
A0042707
21
Connecting supply voltage 24 V DC
1
Terminal blocks
2
Cable entry
3
Power supply cable
1. Route the power supply cable into the housing through the cable gland at
connection
port G
.
2. Connect the protective ground to the green/yellow terminal strip "1".
3. Connect 0 V DC to the blue terminal strip "2".
4. C24 V DC to the gray terminal strip "3".
5. Close the housing → 17.
6.6
Connecting Liquiline CM444 and Modbus Device
Edge
Signal transmission between the Liquiline CM444 transmitter and the Modbus Device
Edge is via the Ethernet cable supplied. The Ethernet connection in the transmitter is
already established on delivery from the factory.