RMS 621
Hauser
5
!
Note!
Only one temperature available for liquid heat quantity. A direction signal teriminal is required on
changing flow direction (bi-directional operating mode).
Steam application
Input values:
Flow, pressure, temperature 1, (temperature 2)
!
Note!
2 temperature sensors are required for steam diferential applications.
Pressure
Select signal type and terminals and then connect sensor (see example).
Type: Relative- or absolute-pressure? Enter start- and end-values.
Temperatur
e
Select signal type and connect sensor(s) (see example). 2 temperature sensors are required for heat differential measurements.
Application
Application: e.g. Water- heat differential
Operating mode: e.g. heating (this means inflow warm, return cold)
Allocate installation point for flow measurement sensor (warm/cold)
Allocate temperature sensors
Flow
Pulse/PFM (e.g. ProWirl)
Analogue (e.g. Promag)
Differential pressure (e.g. Orifice)
Flow
Pulse/PFM (e. g. Prowirl)
Analogue (e. g. Prowirl)
Differential pressure (e. g. Orifice)
Flow input
Flow input
Flow input
Flow meter: Operating volume
Flow meter: Operating volume
Differential pressure/Orifice.../Gas
Terminals:
– Flow meter with active signal connect to e.g. terminals A10(+)/11(-).
– Flow meter with passive signal select e.g. terminals A10 and connect to terminals A10(-)/82(+).
k factor
Start/end value (m
3
/h)
Start/end value (mbar)
Pressure
Select signal type and terminals and then connect sensor (see example).
Type: Relative- or absolute-pressure? Enter start- and end-values.
Temperature
Select signal type and connect sensor(s) (see example). 2 temperature sensors are required for heat differential measurements.
Application
Application (1);
Application: e.g. steam mass
Steam type: e.g. superheated
Allocate sensors for flow, pressure and temperature measurement
Summary of Contents for RMS621
Page 1: ...BA127R 09 en 08 04 510 04788 Software Version 2 0 Operating manual RMS 621 Energy manager ...
Page 6: ...RMS 621 6 Endress Hauser ...
Page 23: ...RMS 621 5 Operation Endress Hauser 23 5 1 2 Display Quick Setup ...
Page 88: ......
Page 90: ...www endress com worldwide BA 127R 09 en 08 04 510 04788 FM SGML6 0 ...