6.2 Technical data: Sensor
Promag F
Nominal diameter
DN 15...2000
Nominal pressure
DIN:
PN 10 (DN 200
…
2000)
PN 16 (DN 65...150)
PN 40 (DN 25...50)
PN 16 /25 (DN 200...300),
Option
PN 40 (DN 65...100), Opt.
20K (DIN 50...300), Opt.
Process connection
Flange connection (DIN, ANSI, JIS)
(DN 15...100)
Flange material
DIN:
St. 37.2,
stainless steel 1.4571
Fluid temperature range,
liner material
–40...+130 °C PTFE (DN 25...600)
–20...+120 °C Soft rubber
(DN 65...2000)
0...+80 °C
Hard rubber
(DN 65...2000)
0...+30 °C
with the fiscal measurement unit,
not dependent upon lining materials
Ambient temperature range
–20...+60 °C
Electrode material
1.4435, Platinum/Rhodium 80/20,
Hastelloy C-22, Tantalum
Electrodes fitted
DN 15...2000: Measuring, reference and EPD
electrodes (standard for 1.4435 and Hastelloy C-22)
Min. conductivity
5
µ
S/cm
Gasket material
—
Housing material
DN 25...300: powder-coated die-cast aluminium
DN 350...2000: varnished steel
Type of protection (DIN 40050)
IP 67 (IP 68 option)
NEMA 4X (NEMA 6P as option)
CIP cleanable
Yes (note max. temperature)
SIP cleanable
—
Power Supply
The sensor is supplied by the measuring transmitter
Explosion protected version
CENELEC: EEx d/de;
Approvals
—
Cable entries
(Remote-mounted version)
PG 11 cable glands (5...12 mm) or
NPT
1
/
2
", M20 x 1.5 (8...15 mm), G
1
/
2
"
6. Technical Data
Promag 31
48
Hauser
Summary of Contents for promag 31
Page 4: ...Promag 31 4 Endress Hauser ...
Page 22: ...2 Mounting and Installation Promag 31 22 Endress Hauser ...
Page 28: ...Promag 31 28 Endress Hauser ...
Page 44: ...5 Fault Location and Remedies Promag 31 44 Endress Hauser ...
Page 56: ...6 Technical Data Promag 31 56 Endress Hauser ...
Page 59: ......