2.5 Turning the transmitter housing and local display
(compact version)
In the compact version the transmitter housing and the local display can be rotated in
steps of 90° relative to the sensor. This enables the unit to be adapted to suit the
various mounting positions in the pipe.
Note!
For instruments with EEx d/de approval the procedure for rotating the instrument
is different than that described here and is given in the Ex supplement to this manual.
Turning the transmitter housing
1. Loosen the two fixing screws of the transmit-
ter bayonet catch (appr. 2 turns).
2. Turn the bayonet catch of the transmitter as
far as the screw slits.
3. Lift the transmitter housing to the stop.
Note!
During servicing (and only then) the trans-
mitter housing can be separated from the
sensor. To do this the corresponding mark-
ing notches on the side of the bayonet
flanges should be brought into alignment.
Do not damage the cable to the sensor
when lifting the transmitter housing.
4. Turn the transmitter housing into the desired
position. Engage the bayonet catch and
re-tighten the two screws.
b
a028
y
1
8
Fig. 20
Turning the local display
Warning!
Danger from electric shock. Switch off the
power supply, before unscrew the cover of
electronics area.
1. Loosen the safety grip of the cover of the
electronics area. Loosen the screw with
a 3 mm Allen key.
2. Unscrew the cover of the electronics area
of the transmitter housing.
3. Unscrew the two Phillips screws which
fasten the display module.
4. Rotate the display module to the required
position.
5. Securely tighten the Phillips screws.
6. Replace and screw down securely the
cover of the electronics area of the transmit-
ter housing.
7. Replace and tighten the safety grip.
b
a
0
28y
19
Fig. 21
2. Mounting and Installation
Promag 31
18
Hauser
Summary of Contents for promag 31
Page 4: ...Promag 31 4 Endress Hauser ...
Page 22: ...2 Mounting and Installation Promag 31 22 Endress Hauser ...
Page 28: ...Promag 31 28 Endress Hauser ...
Page 44: ...5 Fault Location and Remedies Promag 31 44 Endress Hauser ...
Page 56: ...6 Technical Data Promag 31 56 Endress Hauser ...
Page 59: ......