Proline Prosonic Flow 93T Portable
Installation
Hauser
9
2.5
Determining the installation distances
2.5.1 Running the "Sensor Installation" Quick Setup menu
Calling the Quick Setup
All the installation distances required for sensor mounting are determined with the Quick Setup.
!
Note!
If you are not familiar with the operation of the device
→
ä
28.
1.
F
→
Enter the function matrix (starting with measured value display)
2.
P
→
Select the group QUICK SETUP
F
→
Confirm selection
3.
P
→
Select the SENSOR INSTALLATION function
F
→
Confirm selection
4.
Intermediate step if configuration is blocked:
P
→
Enter the code
93
(confirm with
F
) and thus enable configuration
5.
P
→
Go to Sensor Installation Quick Setup
6.
P
→
Select YES
F
→
Confirm selection
7.
F
→
Start Sensor Installation Quick Setup
For subsequent steps, see the following section "Running the Quick Setup for Clamp On type of
mounting".