Proline Promass S 100
42
Hauser
Explosion hazards arising from gas and dust
Determining the temperature class and surface temperature with the temperature table
• In the case of gas: Determine the temperature class as a function of the ambient temperature T
a
and the medium temperature T
m
.
• In the case of dust: Determine the maximum surface temperature as a function of the maximum
ambient temperature T
a
and the maximum medium temperature T
m
.
Example
• Measured maximum ambient temperature: T
ma
= 47 °C
• Measured maximum medium temperature: T
mm
= 108 °C
Ta
[°C]
T1
[450°C]
35
140
50
140
60
140
35
140
45
140
50
140
50
85
120
140
140
–
85
120
140
140
–
–
120
140
140
50
85
120
140
140
–
85
120
140
140
–
–
120
140
140
T6
[85°C]
T5
[100°C]
T4
[135°C]
T3
[200°C]
T2
[300°C]
A0019758
20
Procedure for determining the maximum surface temperature
1. Select device.
2. In the column for the maximum ambient temperature T
a
select the temperature that is
immediately greater than or equal to the measured maximum ambient temperature T
ma
that is
present.
T
a
= 50 °C.
The row showing the maximum medium temperature is determined.
3. Select the maximum medium temperature T
m
of this row, which is larger or equal to the
measured maximum medium temperature T
mm
.
The column with the temperature class for gas is determined: 108 °C ≤ 120°C → T4.
4. The maximum temperature of the temperature class determined corresponds to the maximum
surface temperature for dust: T4 = 135 °C
Storage temperature
–50 to +60 °C (–58 to +140 °F) (Order code for "Test, certificate", option JM)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Degree of protection
Transmitter and sensor
• As standard: IP66/67, type 4X enclosure
• With the order code for "Sensor options", option
CM
: IP69K can also be ordered
• When housing is open: IP20, type 1 enclosure
• Display module: IP20, type 1 enclosure
Safety Barrier Promass 100
IP20
Shock resistance
As per IEC/EN 60068-2-31
Vibration resistance
Acceleration up to 1 g, 10 to 150 Hz, based on IEC/EN 60068-2-6
Interior cleaning
• Sterilization in place (SIP)
• Cleaning in place (CIP)
• Cleaning with pigs