Proline Promag 51
4 Wiring
Hauser
45
4.2.3
Connecting a “reset key” (for error messages)
In custody transfer mode, error messages occurring during operation must be reset or confirmed
manually via the status input (auxiliary input) using a voltage pulse, e.g. via external switches or
reset buttons provided for this purpose.
The power is supplied either by means of an external power source or the current output (Fig. 31).
F06-xxxxxxxx-04-xx-xx-xx-011
Fig. 31:
Wiring versions for connecting a “reset” key (for resetting errors)
A = Wiring version with an external voltage supply (3...30 V)
B = Wiring version with the current output as voltage supply (4...20 mA)
Terminal No. 20 / 21 = Status input
Terminal No. 26 / 27 = Current output
20
A
B
21
3...30 V
20
21
26
27
+
-
+
+
-
-
+
-
Esc
E
-
+
Esc
E
-
+
Summary of Contents for Proline Promag 51
Page 4: ...QUICK SETUP commissioning Proline Promag 51 4 Endress Hauser...
Page 10: ...1 Safety instructions Proline Promag 51 10 Endress Hauser...
Page 52: ...4 Wiring Proline Promag 51 52 Endress Hauser...
Page 80: ...7 Maintenance Proline Promag 51 80 Endress Hauser...
Page 104: ...9 Trouble shooting Proline Promag 51 104 Endress Hauser...
Page 122: ...11 Index Proline Promag 51 122 Endress Hauser...
Page 124: ...www endress com worldwide BA080D 06 en 03 05 50101924 FM SGML6 0...