Proline Promag 51
10 Technical data
Hauser
111
Limiting medium pressure
range (nominal pressure)
The material load diagrams (pressure-temperature graphs) for the process connections are to be
found in the following documents:
• Technical Information “Promag 50/53W” (TI 046D/06/en)
• Technical Information “Promag 50/53P” (TI 047D/06/en)
Promag W:
EN 1092-1 (DIN 2501): PN 6 (DN 1200...2000), PN 10 (DN 200...2000), PN 16 (DN 65...2000),
PN 25 (DN 200...1000), PN 40 (DN 25...150)
Promag P:
EN 1092-1 (DIN 2501): PN 10 (DN 200...600), PN 16 (DN 65...600), PN 25 (DN 200...600),
PN 40 (DN 15...150)
Pressure tightness
(liner)
Limiting flow
Pressure loss
• No pressure loss if the sensor is installed in a pipe of the same nominal diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545
Promag W
Nominal diameter
Measuring
tube lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] at various fluid temperatures
[mm]
[inch]
25 °C
50 °C
80° C
100 °C
130 °C
150 °C
180 °C
25…1000
1…40"
Polyurethane
0
0
−
−
−
−
−
65…2000
3…78"
Hard rubber
0
0
0
−
−
−
−
Promag P
Nominal diameter
Measuring
tube lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] at various fluid temperatures
[mm]
[inch]
25 °C
80 °C
100 °C
130 °C
150 °C
180 °C
15
1/2"
PTFE
0
0
0
100
–
–
25
1"
PTFE / PFA
0 / 0
0 / 0
0 / 0
100 / 0
– / 0
– / –
32
−
PTFE / PFA
0 / 0
0 / 0
0 / 0
100 / 0
– / 0
– / –
40
1 1/2"
PTFE / PFA
0 / 0
0 / 0
0 / 0
100 / 0
– / 0
– / –
50
2"
PTFE / PFA
0 / 0
0 / 0
0 / 0
100 / 0
– / 0
– / –
65
−
PTFE / PFA
0 / 0
*
40 / 0
130 / 0
– / 0
– / –
80
3"
PTFE / PFA
0 / 0
*
40 / 0
130 / 0
– / 0
– / –
100
4"
PTFE / PFA
0 / 0
*
135 / 0
170 / 0
– / 0
– / –
125
−
PTFE / PFA
135 / 0
*
240 / 0
385 / 0
– / 0
– / –
150
6"
PTFE / PFA
135 / 0
*
240 / 0
385 / 0
– / 0
– / –
200
8"
PTFE / PFA
200 / 0
*
290 / 0
410 / 0
– / 0
– / –
250
10"
PTFE
330
*
400
530
–
–
300
12"
PTFE
400
*
500
630
–
–
350
14"
PTFE
470
*
600
730
–
–
400
16"
PTFE
540
*
670
800
–
–
450
18"
PTFE
Partial vacuum is impermissible
500
20"
PTFE
600
24"
PTFE
* No value can be quoted.
Summary of Contents for Proline Promag 51
Page 4: ...QUICK SETUP commissioning Proline Promag 51 4 Endress Hauser...
Page 10: ...1 Safety instructions Proline Promag 51 10 Endress Hauser...
Page 52: ...4 Wiring Proline Promag 51 52 Endress Hauser...
Page 80: ...7 Maintenance Proline Promag 51 80 Endress Hauser...
Page 104: ...9 Trouble shooting Proline Promag 51 104 Endress Hauser...
Page 122: ...11 Index Proline Promag 51 122 Endress Hauser...
Page 124: ...www endress com worldwide BA080D 06 en 03 05 50101924 FM SGML6 0...