Pressure loss
• No pressure loss if the sensor is installed in a pipe of the same nominal diameter.
• Pressure losses for configurations incorporating adapters to DIN EN 545
→
Page 18
Flow characteristics (US units)
Nominal
diameter
Recommended
flow rate
Factory settings
[inch]
[mm]
Min./max. full scale value
(v ~ 1 or ~ 33 ft/s)
Full scale value
(v ~ 8 ft/s)
Pulse weighting
(~ 2 pulse/s)
Creepage
(v ~ 0.1 ft/s)
1/2"
15
1.0 to 27
gal/min
6
gal/min
0.05
gal
0.10
gal/min
1"
25
2.5 to 80
gal/min
18
gal/min
0.20
gal
0.25
gal/min
1 1/4"
32
4 to 130
gal/min
30
gal/min
0.20
gal
0.50
gal/min
1 1/2"
40
7 to 190
gal/min
50
gal/min
0.50
gal
0.75
gal/min
2"
50
10 to 300
gal/min
75
gal/min
0.50
gal
1.25
gal/min
2 1/2"
65
16 to 500
gal/min
130
gal/min
1
gal
2.0
gal/min
3"
80
24 to 800
gal/min
200
gal/min
2
gal
2.5
gal/min
4"
100
40 to 1250
gal/min
300
gal/min
2
gal
4.0
gal/min
5"
125
60 to 1950
gal/min
450
gal/min
5
gal
7.0
gal/min
6"
150
90 to 2650
gal/min
600
gal/min
5
gal
12
gal/min
8"
200
155 to 4850
gal/min
1200
gal/min
10
gal
15
gal/min
10"
250
250 to 7500
gal/min
1500
gal/min
15
gal
30
gal/min
12"
300
350 to 10,600
gal/min
2400
gal/min
25
gal
45
gal/min
14"
350
500 to 15,000
gal/min
3600
gal/min
30
gal
60
gal/min
16"
400
600 to 19,000
gal/min
4800
gal/min
50
gal
60
gal/min
18"
450
800 to 24,000
gal/min
6000
gal/min
50
gal
90
gal/min
20"
500
1000 to 30,000
gal/min
7500
gal/min
75
gal
120
gal/min
24"
600
1400 to 44,000
gal/min
10,500
gal/min
100
gal
180
gal/min