Proline Promag 50P, 53P
Hauser
39
Promag 53P Electromagnetic flowmeter
Nominal Diameter
0
15
1/2”
2F 10”
25
1”
3H 12”
40
1-1/2”
3F 14”
50
2”
4H 16”
80
3”
4F 18”
1H
4”
5H 20”
1F
6”
6H 24”
2H
8”
1
Liner
A
PFA liner, standard (available for 1” to 8” sensors)
B
PFA liner, high temperature version (available for 1” to 8” sensors,
not for approval N)
E
PTFE liner
2
Process connection
L
Class 150 ANSI B16.5 CS steel A105 flanges
M
Class 300 ANSI B16.5 CS steel A105 flanges (not for 8” and larger)
R
Class 150 ANSI B16.5 316L SS flanges
S
Class 300 ANSI B16.5 316L SS flanges (not for 8” and larger)
3
Electrodes / material
0
Measuring, reference and EPD electrodes / 316L SS
1
Measuring, reference and EPD electrodes / Alloy C22
2
Measuring, reference and EPD electrodes / tantalum
3
Measuring electrodes only, Platinum/Rhodium 80/20% (not available for
14” to 24”)
5
Measuring, reference and EPD electrodes, Platinum/Rhodium 80/20% (not
available for 14” to 24”)
G
Measuring, reference and EPD electrodes, bullet nose / 316L SS
H
Measuring, reference and EPD elecctrodes, bullet nose / Alloy C-22
4
Calibration
B
3-point calibration, 0.2%
E
SCS/A2LA 3-point 0.2% calibration (ISO/IEC 17025) with certificate
traceable according to ISO 9000 (specify range)
5
Certificates
1
Standard, no certificate
2
3.1B material certificate for pipe and flanges
3
2.3 pressure test certificate (1.5 x PN, 3 minutes)
4
3.1B material and 2.3 pressure test certificate
6
Approvals
A
For use in non-hazardous areas
N
FM explosion proof Class I, Div. 1 / CSA Class I, Div. 1 (only for aluminum
field housing, compact version, not for 14” and larger sensors)
R
FM non-incendive Class I, Div. 2 / CSA Class I, Div. 2
*
Housing options
Harsh environment (HE) option is available for process conditions where
cool process temperatures in tropical (high humidity) environments or process
fluids which undergo large cyclical temperature variations which can cause
high amounts of moisture that could condense onto the measurement tube.
Promag 53 P -
0 1 2 3 4 5 6 7 8 9 10 11 12
7
Housing
A
NEMA 4X (IP 67) compact aluminum housing
C
NEMA 4X (IP 67) remote wall-mounted (only for approvals A or R)
G
NEMA 4X (IP 67) remote aluminum field housing for non-hazardous areas
K
NEMA 6P sensor, wall-mounted housing (only for approvals A or R)
N
NEMA 6P sensor, aluminum field housing, non-hazardous, not for
liner B high temp. (only up to 12” sensor)
P
NEMA 4X (IP 67) compact aluminum housing, HE (harsh environment),
compact and remote sensor sizes up to 12” only *
S
NEMA 4X (IP 67) remote wall-mounted housing, HE (harsh environment),
remote sensor sizes 14” to 24” (only for approvals A and R),
available as TSP only *
T
NEMA 4X (IP 67) remote field housing, HE (harsh environment),
remote sensor sizes 1/2” to 12” only *
1
-40°F (-40°C) ambient temperature, NEMA 4X (IP 67), compact,
aluminum field housing (only for approvals A and R)
3
-40°F (-40°C) ambient temperature, NEMA 4X (IP 67), compact,
(only for approvals A and R)
5
-40°F (-40°C) ambient temperature, NEMA 6P sensor, wall mount
housing for transmitter (only for approvals A and R)
6
-40°F (-40°C) ambient temperature, NEMA 4X (IP 67) remote field
housing (only for approvals A and R)
8
Cable for remote
0
Without cable
1
15 foot coil and signal cable
2
30 foot coil and signal cable
5
Coil and signal cable, specify length (maximum 650 ft depending on
conductivity of process material)
9
Cable entries
B
1/2” NPT
L
1/2” NPT fieldbus connector (only for approval A and R)
X
Sensor only, without cable, compact version, up to 8” only
10
Power supply / display
7
85 to 260 VAC, without display, remote configuration only (not for
wall mount or SS housing)
8
20 to 55 VAC / 16 to 62 VDC, without display, remote configuration
only (not for wall mount or SS housing)
A
85 to 260 VAC, with display, push button operation (language: EN,
ES, FR, IT, NL, PT, DE)
B
20 to 55 VAC / 16 to 62 VDC, with display, push button operation
(language: EN, ES, FR, IT, NL, PT, DE)
X
Sensor only (without transmitter, only available up to 8”)
11
Software
A
Standard software
C
ECC electrode cleaning circuit (only for approvals A and R)
12
Outputs / Inputs
Fixed communication boards
A
Current HART, frequency
B
Current HART, frequency, 2 relays
F
PROFIBUS-PA, IS
G
Foundation Fieldbus, IS
H
PROFIBUS-PA
J
PROFIBUS-DP
K
Foundation Fieldbus
Q
Modbus RS485, status input
S
Current HART, frequency; active I.S
T
Current HART, frequency; passive I.S
Flexible communication boards
C
Current HART, frequency, 2 relays, flexible module
D
Current HART, frequency, relay, and status input, flexible module
L
Current HART, 2 relays and status input/output
M
Current HART, 2 frequency output, status input
N
Modbus RS 485, current and frequency output, status input
P
PROFIBUS-DP, current and frequency output, status input
V
PROFIBUS-DP, two relay outputs, status input
2
Current HART, relay, current, frequency ouputs
4
Current HART, relay, frequency outputs, current input
7
Modbus RS485, two relay outputs, status input
X
Sensor only