Proline Promag 300 Modbus RS485
Description of device parameters
Hauser
29
Last backup
Navigation
Expert → System → Config. backup → Last backup (2757)
Description
Displays the time since a backup copy of the data was last saved to the device memory.
User interface
Days (d), hours (h), minutes (m) and seconds (s)
Config. managem.
Navigation
Expert → System → Config. backup → Config. managem. (2758)
Description
Use this function to select an action to save the data to the device memory.
Selection
• Cancel
• Execute backup
• Restore
• Compare
• Clear backup
Factory setting
Cancel
Additional information
Selection
Options
Description
Cancel
No action is executed and the user exits the parameter.
Execute backup
A backup copy of the current device configuration is saved from the HistoROM
backup to the memory of the device. The backup copy includes the transmitter data
of the device.
The following message appears on local display: Backup active, please wait!
Restore
The last backup copy of the device configuration is restored from the device
memory to the device's HistoROM backup. The backup copy includes the
transmitter data of the device.
The following message appears on local display: Restore active! Do not interrupt
power supply!
Compare
The device configuration saved in the device memory is compared with the current
device configuration of the HistoROM backup.
The following message appears on local display: Comparing files
The result can be viewed in
Compar. result
parameter.
Clear backup
The backup copy of the device configuration is deleted from the memory of the
device.
The following message appears on local display: Deleting file
HistoROM
A HistoROM is a "non-volatile" device memory in the form of an EEPROM.